Pos : 37 /Bedienungs anl eitungen/ Prodis/F unkti onen_T abelle- INC @ 6\ mod_1508321495698_78. doc x @ 48857 @ @ 1
Operation of the functions
‒ chart
Submenus
Parameter
Display
Value range
Factory setting
+
Decimal point
dp
1 bis 5, OFF
OFF
Z signal active/inactive
rEF
1 / 0
0
Reset button
active/inactive
nu l
1 / 0
1
Automatic relative
measurement reset
CHnu l
1 / 0
1
Multiplier
ZAEHLE
0 ... +999999
000001
Divisor
nEnnEr
0 ... +999999
000001
Counting direction
drEh L/r
left / right
L
T signal
t
oFF/CS/CF/Hn/AF/tl/
brEF/Ctr3/Ctr4
oFF
Last value memory
ISt
1 / 0
0
Display brightness
db
1 ... 15
15
Transmission rate
bA
4.8, 9.6 ... 115.2
9.6
+
Relative measurement
mode
Flashing
decimal point
0
Reset
Offset
oFFSEt
-999999 ... +999999
000000
+
Limit value
rELx
+/- 999.999
+999.999
Hysteresis
Hµ rELx
+/- 999.999
1
Operating direction
rx
oEF, SCH
SCH
Measurement mode
rx
HAU / CHA
HAU
+
Reset to factory
default value
000000 for 2 s
+ power on*
* Disconnect device from excitation, wait 5 seconds, press both arrow keys together and hold.
Connect excitation, the display shows “000000”, then release both arrow keys.