PAGE 4

 

 User Manual BS 286 / February 2011 © ASL Intercom BV 

 

 

 

 

2.0 

UNPACKING 

 
The shipping carton contains the parts listed below 

The BS 286 

Mains power cable 

Spare fuses 

User manual 

 
If any are missing, contact your dealer. 
 
 

ASL has taken great care to ensure that this product 
reaches you in flawless condition.  
After unpacking the unit please inspect for any 
physical damage to the unit, and retain the shipping 
carton and relevant packing materials for use should 
the unit need returning. If any damage has occurred, 
please notify your dealer immediately so that a 
written claim can be initiated. Please also refer to the 
warranty section of this manual. 

 

3.0 

WARRANTY 

 
This unit is warranted by ASL Intercom to the original 
end-user purchaser against defects in workmanship 
and materials in it's manufacture for a period of one 
year from date of shipment to the end-user. 
 
 

Faults arising from misuse, unauthorized modifications 
or accidents are not covered by this warranty. If the 
unit is faulty it should be sent in its original packing, to 
the supplier or your local ASL dealer, with shipping 
prepaid. A note must be included stating the faults 
found and a copy of the original suppliers invoice. 

 

 4.0 

MECHANICAL INSTALLATION 

 
For the BS 286 a 

vertical rack space of 1U (1.75”, 

44mm) is required. It is not necessary to provide 
rear support by extra bracing or shelving. Adequate 
ventilation must be provided by allowing sufficient 
space around the sides and rear of the unit to 
ensure free circulation of air.  

Forced cooling is not required. 
 
The power supply regulator is mounted on the rear 
of the unit; after a period of time it will feel hot to the 
touch. This is quite normal, and should be no cause 
for alarm.

 

 5.0 

MAINS POWER & SAFETY EARTH 

 

Connecting to mains power 

The BS 286 may be connected to a mains power outlet 
which provides 100 

– 240 V AC, 50-60 Hz and at least 

60 watts. The outlet should have a clean earth. Avoid 
using mains power outlets which also power dimmer 
controlled lighting equipment. 
 
The wires in the mains lead are color coded:  
green/yellow: 

Earth / safety ground 

blue: 

 

Neutral 

brown:   

Live 

 
In case the wires in the mains lead do not correspond 
with the colored markings identifying the terminals in 
your mains plug, proceed as follows: 

 

The wire which is colored green/yellow must 
be connected to the terminal in the plug which 
is marked with the letter “E”, or by the ground 
symbol, or is colored green. 

 

The wire which is colored blue must be 
connected to the terminal which is marked with 
the letter “N” or colored black. 

 

The wire which is colored brown must be 
connected to the terminal which is marked with 
the letter “L” or colored red. 

 

Safety Earth 

 

The green/yellow wire of the mains lead must 
always be connected to the electrical installation 
safety earth or ground

. This is essential for personal 

safety as well as for proper operation of the BS 286 
and the other connected stations. The green/yellow 
wire is in the BS 216 connected to all exposed metal 
surfaces. Any rack framework into which this unit might 
be mounted is assumed to be connected to the same 
grounding circuit. 

 

6.0 

GENERAL DESCRIPTION 

 
The BS 286 is a dual channel power supply and can 
be used in an ASL intercom system.  The unit is 
ideal for use in applications  where standard 
microphone cable is available and ease of setup is 
of paramount importance.. The unit  can drive at 
least 10 beltpacks operating at full power.  
 
The dual channel power supply is fully protected 
against wiring mistakes (reverse power), short circuit 
or  dangerous thermal condition.  

Should one of these conditions occur, the unit shuts 
down. Once  the fault condition has been removed, 
the BS 286 resets automatically and full power is 
restored.  
 
An Aux input at the rear panel allows injecting 
external audio signals of line or mic level into the 
intercom lines. When „mic level‟ is selected, +30V 
phantom power is available at the Aux input 
connector. 

Summary of Contents for BS 286

Page 1: ...ER SUPPLY USER MANUAL February 2011 ASL Intercom BV DESIGNED MANUFACTURED BY ASL Intercom B V Zonnebaan 42 3542 EG Utrecht The Netherlands Tel 31 0 30 2411901 Fax 31 0 30 2667373 Email info asl inter com Web www asl inter com ...

Page 2: ...NTY 4 4 0 MECHANICAL INSTALLATION 4 5 0 MAINS POWER SAFETY EARTH 4 6 0 GENERAL DESCRIPTION 4 7 0 FRONT PANEL CONTROLS CONNECTOR 5 8 0 REAR PANEL CONTROLS CONNECTORS 5 9 0 TECHNICAL SPECIFICATIONS 5 10 0 PARTY LINE TECHNICAL CONCEPT 6 11 0 CABLING 6 12 0 EARTHING CONCEPT 7 13 0 BS 286 BLOCK DIAGRAM 7 14 0 POSSIBLE SYSTEM CONFIGURATION 8 ...

Page 3: ...g the apparatus power cord by gripping the power plug not the cord 11 Insert the plug properly Do not defeat the safety purpose of the polarized or grounding type plug An American polarized AC line plug has two blades with one wider than the other This plug will fit only one way into the power outlet This is a safety feature If you are unable to insert the plug fully into the outlet try reversing ...

Page 4: ...Hz and at least 60 watts The outlet should have a clean earth Avoid using mains power outlets which also power dimmer controlled lighting equipment The wires in the mains lead are color coded green yellow Earth safety ground blue Neutral brown Live In case the wires in the mains lead do not correspond with the colored markings identifying the terminals in your mains plug proceed as follows The wir...

Page 5: ... level When mic level is selected 30V DC phantom power is supplied to pin 2 and 3 of the AUX input connector With the MIC GAIN trimmer one can adjust the input sensitivity when mic level is selected 6 FUSE Holder The fuse protects the BS 286 against severe internal damage in case of malfunction in the power section Before replacing a fuse the mains cord must be disconnected from the mains outlet 7...

Page 6: ...cially when the cable is subjected to bending during operation or installation Cable screens to XLR pin 1 The screen of each separate microphone cable and or the screen of each single pair in a multi pair cable should be connected to pin 1 of each XLR 3 connector Do not connect these screens to the metal housing of ASL unitst or XLR 3 wall boxes See section Earthing Concept Connect metal cable tru...

Page 7: ...PAGE 7 User Manual BS 286 February 2011 ASL Intercom BV 12 0 EARTHING CONCEPT 13 0 BS 286 BLOCK DIAGRAM ...

Page 8: ...PAGE 8 User Manual BS 286 February 2011 ASL Intercom BV 14 0 POSSIBLE SYSTEM CONFIGURATION ...

Reviews: