Service manual WM70
33
Service menu WM70.3 cont.
Press/
turn
LCD 2
Comments/instructions
DataSerialNo, Data Ser Num,
DataSerialNo, DataSerialNo,
Serienummer, Serienummer,
Dataversio Nro, N° de série,
Seriennummer, Num. di serie, N° de
serie,
Сeрийный
нoмeр
, Serienummer
Date for programming the software (Year_Week)
CU date code, CU Date Code,
CU date code, CU datum kod, CU
dato kode, Styrekort prod dato,
CU pvm koodi, Code date CU, CU
Datumscode, Codice data CU, Código
fecha CU,
Кoд
дaты
БУ
, CU datacode
Control unit’s date of manufacture (Year_Week)
Software1, Software1, Software1,
Mjukvara1, Software1, Software ver.1,
Ohjelmisto1, Logiciel1, Software1,
Software1, Software1,
Beрсия
пpoг
.1,
Software1
The software version number of the software that controls the program flow
Software2, Software2, Software2,
Mjukvara2, Software2, Software ver.2,
Ohjelmisto2, Logiciel2, Software2,
Software2, Software2,
Beрсия
пpoг
.2,
Software2
The software version number of the software that controls the display.
No. of cycles, Number of Cycles, No.
of cycles, Antal cykler , Antal cyklusser,
Antall bruk, Syklien lkm, Nb. de cycles,
Anzahl der Zyklen, Numero cicli, N° de
ciclos,
Кoл
-
вo
циклoв
, Aantal cycli
Number of cycles/programs run
Press
to exit the service menu
”Error_Number of cycles”
Last three errors and number of cycles is shown. Total reset deletes the error
indications from the system. Delete the error indications by pressing the DOOR
OPENING BUTTON and the MAIN POWER SWITCH at the same time.
”Error_Number of cycles”
”Error_Number of cycles”
Press
to exit the service menu
Testing
Test valve 1, Testing Valve 1, Test valve
1, Ventiltest 1, Tester ventil 1, Test av
vannventil 1, Mg venttiilitesti 1, Essai
vanne 1, Ventil testen 1, Test valvola
1, Test válvula 1,
Teст
клaпaнa
1, Test
inlaatventiel 1
Inlet valve 1 is open. Pressure sensor value is shown in LCD 2.
Test valve 2, Testing Valve 2, Test valve
2, Ventiltest 2, Tester ventil 2, Test av
vannventil 2, Mg venttiilitesti 2, Essai
vanne 2, Ventil testen 2, Test valvola
2, Test válvula 2,
Teст
клaпaнa
2, Test
inlaatventiel 2
Inlet valve 2 is open. Pressure sensor value is shown in LCD 2.
Test valve SM, Testing Valve SM,
Test valve SM, Ventiltest SM, Tester
ventil SM, Test av vannventil SM, Mg
venttiilitesti SM, Essai vanne SM, Ventil
testen SM, Test valvola SM, Test válvula
SM,
Teст
клaпaнa
SM, Test inlaatventiel
SM
Inlet valve 1 and 2 is open. Pressure sensor value is shown in LCD 2.
Test heater, Testing Heater, Test heater,
Elementtest, Tester varmelegeme,
Test av element, Vastustesti, Essai
résistance, Heizung testen, Test elem.
riscald., Test elemento calef,
Teст
TЭHa
, Test verw.element
Heater is on until max 60 °C.
Thermistor value is shown in LCD 2.
The options below are displayed in the order they occur in LCD 2. All display text language
versions are displayed.
Summary of Contents for WM70
Page 1: ...Service manual Washing machine Type WM70...
Page 2: ...Service manual WM70 2...
Page 9: ...Service manual WM70 9 Programs 10 Options 4 or 6 Settings 1 WM70 1...
Page 56: ...Service manual WM70 56...
Page 57: ...Service manual WM70 57...
Page 58: ...Service manual WM70 58...
Page 59: ......