Selecting the location
Place the appliance in a dry and well aired
room. The permitted ambient temperature
range for the appliance depends on the
appliance’s climate class, which is shown on
the type plate.
WARNING!
Do not place the appliance in a room where the temperature can fall below 41°F (5°C): the
appliance may not work properly or become defective!
Relative humidity
Ambient temperature range °C
Class
Description
≤75%
50 to 90°F (10 to 32°C)
SN
Extended temperate
61 to 90°F (16 to 32°C)
N
Temperate
61 to 100°F (16 to 38°C)
ST
Subtropical
61 to 109°F (16 to 43°C)
T
Tropical
•
In environments with high humidity level, condensate droplets may appear on the appliance’s
exterior surfaces.
•
If the appliance is installed in a dry environment, we recommend to use humidity box included
in the appliance.
WARNING!
Install the appliance in a room with an adequate amount of air. There should be at least 35.3
cubic feet (1 m
3
) of air per every 0.28 oz (8 g) of refrigerant. The amount of refrigerant is indicated
on the rating plate inside the appliance.
WARNING!
Do not place the appliance in a room where temperature can drop to below 41°F (5°C). In such
environment, the appliance may not operate correctly, or it may become defective.
WARNING!
The appliance is not suitable for outdoor use and it may not be exposed to rain.
11
Installation and connection