![Asko T884XL Operating Instructions Manual Download Page 20](http://html1.mh-extra.com/html/asko/t884xl/t884xl_operating-instructions-manual_2983875020.webp)
20
Customer Care Center, 1-800-898-1879, www.askona.com
INSTALLATION
Electrical Connections !
WARNING !
Read the Electrical requirements and grounding
instructions before connecting the tumble dryer.
Electric models of the dryer are manufactured for a
3-wire connection system. The dryer frame is grounded
by a link to the neutral conductor on the dryer terminal
block. If local codes do not permit grounding through the
neutral, the grounding link from the terminal block must
be removed and a separate ground wire must be used.
Only a 4-conductor cord shall be used when the
appliance is installed in a location where grounding
through the neutral conductor is prohibited. Grounding
through the neutral conductor is prohibited for new
branch-circuit installations, mobile homes, recreational
vehicles, and areas where local codes prohibit grounding
through the neutral conductors. The grounding link on the
dryer must be removed for all 4-wire installations.
These Electrical Connection instructions provide for
installing the dryer in the following situations:
3-wire connection where local codes permit grounding
through the neutral. 3-wire connection plus separate
grounding connector where local codes do not permit
grounding through the neutral.
4-wire connection.
Each of the above connections can be made with an
approved power supply cord or by direct wiring. Each
connection instruction identifies the appropriate Power
Supply Cord and covers requirements for direct wiring.
NOTE!
In Canada, the dryer is delivered ready-fitted with a
four-prong plug intended for connection to a single-
phase supply.
Connecting a 3-wire Power Cord
WARNING !
Before starting this procedure, be sure the power is
turned off at the breaker/fuse box.
Ground
Ground
(center)
Power Supply Cord
You will need a 3-wire power supply cord with three No.
10 copper wires and a matching 3-wire receptacle of
NEMA Type 10-30R, as illustrated below:
To connect a 3-wire power cord to the dryer, follow the
steps below.
NOTE!
The numbers in the illustration correlate to the step
numbers.
1. Turn the power off at the breaker or fuse box.
2. Remove terminal block cover.
3. Use the strain relief attached below the terminal block
opening.
4. Loosen or remove center terminal block screw.
4
5
6
5. Connect ground (center) wire of power supply cord
to the center, silver-colored terminal screw. Tighten
screw.
6. Connect the other wires to outer screws.
7. Tighten the strain relief screws.
8. Replace terminal box cover on back of dryer.