16
Care and cleaning
Emptying the condensed water
container
If you have not connected the machine to a
separate drain the condensed water container
must be emptied after each load. Remove the
condensed water container, empty out the water
and replace the container.
If the condensed water container becomes full
to over
fl
owing, the programme is interrupted
and "Over Flow" appears on the display. Empty
the container and press the Start button to
restart the programme.
For connection to a separate drain, see the
installation instructions in the set of documents.
NOTE!
The dryer must not be used without the
condenser unit in place.
Cleaning the evaporator
fi
lter and
evaporator
Clean the evaporator and the evaporator
fi
lter at
the intervals shown on the machine's display or
more often.
1. Turn o
ff
the Main power switch and open the
outer door.
2. Remove the plinth.
3. Open the evaporator door.
4. Pull out the
fi
lter by grasping the "handle" in
the middle.