Drainage connection
See the separate installation instructions for all
necessary information.
The drainage hose may be extended by a maximum
of 3 m (the total length of the drainage hose must not
exceed 4,5 m). Any joins and connecting pipes must
have an internal diameter of at least 14 mm. However,
the drainage hose should ideally be replaced with a
new hose without joins.
No part of the drainage hose may be more than 950
mm above the bottom of the dishwasher. The hose
must not be routed directly to the floor drain or similar.
In such cases, the hose can act as a siphon and
empty the dishwasher.
The hose must always discharge at least 350 mm
above the bottom of the machine.
Ensure that the drainage hose has no kinks.
NOTE!
The hose must be attached at the same height as
the underside of the sink.
Connection to water supply
Use only the supply hose provided with the
dishwasher. Do not re-use old hoses or other spare
supply hoses.
The supply pipe must be fitted with a stopcock. The
stopcock must be easily accessible, so that the water
can be shut off if the dishwasher has to be moved.
Once the installation is complete, the stopcock should
be opened to allow the pressure to settle for a while
and to check that all connections are tight.
Connect to cold water...
If you use oil or electricity to heat your home.
Connect to hot water (max. 70 °C)...
If you use, for example, district heating, solar power
or geothermal power to heat your home.
NOTE!
Connecting a dishwasher to the water supply via
certain types of pressure limiting valves may restrict
the water supply!
This may cause the error message Water inlet fault
to be displayed.
Electrical connection
Information about the electrical connection can be
found on the serial number plate This specification
must match the electricity supply.
Dishwashers fitted with a plug must be connected to
an earthed socket.
The electric wall socket must be placed outside of the
installation area to be easily accessible after installing
the dishwasher. Do not use an extension cord!
NOTE!
Repairs and maintenance must be carried out by a
qualified professional.