UNIT  DIMENSIONS

US

Metric

Measurements

Measurements

Height

32-1/4"–35-1/2"

819–902 mm

Width

*24"

610 mm

Depth

23-5/8"

600 mm

Weight

106 lb

48 kg

DIMENSIONS

The best place for your dishwasher is in the kitchen
near the sink. This makes it easier to connect the water
and drain supply lines.

A built-in dishwasher must be enclosed on the top,
both sides and the back.

The electrical and water supplies should enter through
the area indicated by the shading on the illustration at
right.

Access holes must be round and smooth, and they
should be 1-1/2” to 2” (38 to 50 mm)  in diameter.

EUROPEAN  INSTALLATIONS

The kick plate supplied with your dishwasher fits a 24"
(610 mm) opening. When using European standard
installation, a 23-1/2” (597 mm) wide toe kick is available
from your ASKO dealer. (Part numbers: White=8073566-
0; Black=8073566-86.)

For a 6” toe kick installation, the part numbers are:
White=8073567-0; Black=8073567-86.

PREPARING  THE  LOCATION

CABINET  OPENING

US

Metric

Measurements

Measurements

Height

32-1/4"–35-1/2"

819–902 mm

Width*

24-1/8”"

613 mm

Depth

23-7/16"

596 mm

23-7/16"

596 mm

24-1/8

613 mm

32-1/4 to 35-1/2" minim

um

819 to 902 mm

2"

50 mm

6-1/4" to 8-1/4"
159 to 210 mm

2-1/4"

57 mm

6-1/4"

159 mm

32-1/4 to 35-1/2"

819 to 902 mm

23-5/8"

600 mm

46-5/8"

1184 mm

Door

6-1/4" - 8-1/4"

159 - 210 mm

2"

50 mm

24"

610 mm

*Models D3250FI and D3530FI are 23-5/8” wide.

Summary of Contents for D3250FI

Page 1: ...CE Introduction 2 What You Need 2 Dimensions 3 Preparing the Location 3 Water Supply 4 Drain Connections 5 Electrical Connections 6 Preparing the Dishwasher for Installation 6 Moving the Machine into Place 7 Connecting the Electric Cable 8 Connecting the Water Supply 8 Adjusting the Leveling Legs 8 Fastening the Dishwasher to the Cabinet 9 Installing the Toe Kick 9 Fitting the D3250 and D3530 Cust...

Page 2: ...ng element 1200 W Max loading 1300 W Read these instructions carefully and completely before you install the machine The installation should be carried out by a qualified person who is familiar with all local codes and ordinances for electrical and plumbing connections If a dishwasher is being installed in this area for the first time most of the cabinet work plumbing and electrical has to be done...

Page 3: ...ameter EUROPEAN INSTALLATIONS The kick plate supplied with your dishwasher fits a 24 610 mm opening When using European standard installation a 23 1 2 597 mm wide toe kick is available from your ASKO dealer Part numbers White 8073566 0 Black 8073566 86 For a 6 toe kick installation the part numbers are White 8073567 0 Black 8073567 86 PREPARING THE LOCATION CABINET OPENING US Metric Measurements M...

Page 4: ...from the side wall so the door can open EASYINSTALL CONNECTIONS Drain hose boot Ready to be cut to desired drain connection Only one clamp required PEX tubing with 3 8 compression fitting PEX tubing has a 95 year spec life Fits American dishwasher water supply valves WATER SUPPLY 1 Water supply 2 Water supply valve not supplied In order to prevent heat damage to the inlet valve all solder connecti...

Page 5: ...ght To eliminate potential drain problems simply leave this hose in place IMPORTANT THINGS TO REMEMBER Failure to provide the proper drain connection height minimum of 20 508 mm above the bottom of the dishwasher base or a 20 508 mm high loop will result in improper drainage which will damage the machine No part of the drain hose should be higher than 35 889 mm from the bottom of the dishwasher Th...

Page 6: ...dishwasher wiring At this point the styrofoam plastic wrap and the wood pallet base should be removed from the dishwasher Now is an excellent time to inspect for any shipping damage Should you find any damage you should report it to your dealer or builder immediately Be sure to remove the toe kick and toe kick insulation which are wrapped in heavy brown paper and packed inside or on top of the dis...

Page 7: ... the drain hose to ensure there are no sharp bends 4 Start to feed water and drain lines and electric cord if necessary into the access hole in the cabinet 5 Gently slide the unit into the dishwasher opening As you do this feed the drain line and inlet hose into the access hole in the side of the cabinet WARNING Be careful of sharp edges As you slide the unit into place feed the drain line and inl...

Page 8: ...ater pressure should be 18 176 psi Be sure to run the PEX tubing through the hole to sink compartment before moving the dishwasher into position NOTE under the dishwasher and sink 4 Make sure that no kinks have developed in the drain lines If there are no leaks and the dishwasher seems to be working properly continue with the installation CONNECTING THE WATER SUPPLY 1 Water supply 2 Water supply v...

Page 9: ... the back side of the toe kick making sure you don t cover any slots on the toe kick 4 Positioning the notches on the toe kick at the edge of the access panel slide the toe kick up behind the access panel then let it slide to the floor 5 Screw the toe kick to the toe kick brackets 6 Adjust the toe kick depth INSTALLING THE TOE KICK It s necessary to fasten the dishwasher to the cabinet so it won t...

Page 10: ...in to install the panel Refer to the illustration at right for instruction references 1 Fit the handle A onto the panel according to the manufacturer s instructions NOTE A handle should be used rather than a knob because a knob does not provide enough grip 2 Loosen the screws D on the outer edges of the dishwasher door 3 Pull the turbo fan exhaust frame E down until the lower edge aligns with the ...

Page 11: ...hich eliminates the need for a decorative fill strip D3250FI AND D3530FI CUSTOM PANEL INSTALLATION OPTIONS 6 inch Toe Kick Installations For 6 toe kick installations the decorative fill strips or support strips are unnecessary A stainless steel fill strip is also available for this type of installation part number 8073869 95 Panel extends from toe kick to cabinet top 4 inch toe kick 30 1 16 764 mm...

Page 12: ...astening unit to cabinet 9 Fill strips 6 Fully integrated door panels 10 G Grounding instructions 6 H Heating element 2 High loop 5 Hot water supply 4 L Leaks testing for 8 Leveling legs adjusting 9 M Materials 2 Moving unit into place 7 P Panels fully integrated 11 Placing the unit 7 Power 2 S Slides for rear legs 6 T Technical data 2 Tip guards 2 installing 4 Toe kick installation options on FI ...