Askey AP6275S User Manual Download Page 16

 

Recommended Reflow Profile

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Summary of Contents for AP6275S

Page 1: ... 5 85GHz Ch149 Ch165 Antenna Type PIFA antenna Hardware version V01 Software Version Android 10 Product Features IEEE 802 11 Key Feature Lead Free design which is compliant with ROHS requirements TX and RX low density parity check LDPC support for improved range and power efficiency Dual stream spatial multiplexing up to 1200 Mbps data rate 20 40 80 MHz channels with optional SGI 1024 QAM modulati...

Page 2: ...for supporting future specifications With Bluetooth Class 1 or Class2 transmitter operation Supports extended synchronous connections eSCO for enhanced voice quality by allowing for retransmission of dropped packets Adaptive frequency hopping AFH for reducing radio frequency interference A simplified block diagram of the module is depicted in the figure above ...

Page 3: ...Type of Modulation 802 11b DSSS 802 11g n OFDM 802 11ax OFDMA Frequency Range For 802 11a n HT20 ac VHT20 ax HE20 5180 5240MHz 5260 5320MHz 5500 5720MHz 5745 5825MHz For 802 11n HT40 ac VHT40 ax HE40 5190 5230MHz 5270 5310MHz 5510 5710MHz 5755 5795MHz For 802 11ac VHT80 ax HE80 5210MHz 5290MHz 5530MHz 5610MHz 5690MHz 5775MHz Type of Modulation 802 11a n ac OFDM 802 11ax OFDMA Operating Frequency 2...

Page 4: ...External clock reference ...

Page 5: ... interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one of the following measures o Reorient or relocate the receiving antenna o Increase the separation between the equipment and receiver o Connect the equipment into an outlet on a circuit different from that to which the receiver is...

Page 6: ...tre le fonctionnement Caution The device for operation in the band 5150 5250 MHz is only for indoor use to reduce the potential for harmful interference to co channel mobile satellite systems Avertissement Le dispositif fonctionnant dans la bande 5150 5250 MHz est réservé uniquement pour une utilisation à l intérieur afin de réduire les risques de brouillage préjudiciable aux systèmes de satellite...

Page 7: ...ther than what is permitted in Part 15 Subpart B or emissions are complaint with the transmitter s rule s The Grantee will provide guidance to the host manufacturer for Part 15 B requirements if needed IMPORTANT NOTE Notice that any deviation s from the defined parameters of the antenna as described by the instructions require that the host product manufacturer must notify to Askey that they wish ...

Page 8: ...ulations limiting both maximum RF output power and human exposure to RF radiation maximum antenna gain including cable loss must not exceed Antenna Specification Antenna Type Frequency Band GHz TX Paths Per Chain Max Antenna Gain dBi CDD Directional Gain dBi Ant 0 Ant 1 For Power For PSD Wi Fi Internal Antenna PIFA 2412 2462 2 2 1 1 9 2 1 5 11 5180 5240 2 4 2 1 9 4 2 7 21 5260 5320 2 3 8 3 0 3 8 6...

Page 9: ... compliance testing with the modular transmitter installed 1 List of applicable FCC rules KDB 996369 D03 Section 2 2 Complies with FCC Part 15 247 Part 15 407 2 Summarize the specific operational use conditions KDB 996369 D03 Section 2 3 Refer to Antenna specification 3 Limited Module Procedures KDB 996369 D03 Section 2 4 This module is approved as single module 4 Trace antenna designs KDB 996369 ...

Page 10: ...nna As long as 2 conditions above are met further transmitter test will not be required However the OEM integrator is still responsible for testing their end product for any additional compliance requirements required with this module installed Radiation Exposure Statement This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment This equipment should be ...

Page 11: ...its set forth for an uncontrolled environment This equipment should be installed and operated with minimum distance 20 cm between the radiator your body Déclaration d exposition aux radiations Cet équipement est conforme aux limites d exposition aux rayonnements ISED établies pour un environnement non contrôlé Cet équipement doit être installé et utilisé avec un minimum de 20 cm de distance entre ...

Page 12: ...n is no longer considered valid and the IC ID cannot be used on the final product In these circumstances the OEM integrator will be responsible for re evaluating the end product including the transmitter and obtaining a separate Canada authorization NOTE IMPORTANTE Dans le cas où ces conditions ne peuvent être satisfaites par exemple pour certaines configurations d ordinateur portable ou de certai...

Page 13: ...ormation to the end user regarding how to install or remove this RF module in the user s manual of the end product which integrates this module The end user manual shall include all required regulatory information warning as show in this manual Manuel d information à l utilisateur final L intégrateur OEM doit être conscient de ne pas fournir des informations à l utilisateur final quant à la façon ...

Page 14: ...Dimensions ...

Page 15: ...Label ...

Page 16: ...Recommended Reflow Profile ...

Page 17: ...Package Information ...

Page 18: ......

Reviews: