![ASKAYNAK Plasma 65 Ultra User Manual Download Page 16](http://html.mh-extra.com/html/askaynak/plasma-65-ultra/plasma-65-ultra_user-manual_2983170016.webp)
50
Maintenance and Troubleshooting - 2
Caution!
For every kind of maintenance and repair operations, contact to the nearest authorized Kaynak
Teknigi Sanayi ve Ticaret A.S. technical service. Maintenance or repairs performed by unauthorized
technical services or personnel will void the manufacturer’s warranty.
1- The plasma cutting machine is checked against any defects before leaving the factory. Therefore, do
not allow unauthorized persons to tamper with the machine.
2- The repair works must be carried out only by the “Authorized
Technical Services” allowed by Kaynak Tekniği Sanayi and Ticaret A.Ş.
3- Watch out for the air pressure while cleaning in order to protect the smaller components. Never direct
water in to the machine for cleaning.
4- The plasma cutting machine should not be cleaned with volatile and synthetic cleaners. Use a moist
and soapy piece of cloth for cleaning the exterior.
5- The maintenance works must be carried out with care. Kinking or wrong connection of a cable may be
very dangerous for the user.
6- Ingress of water or steam should not be allowed in to the plasma cutting machine. If the machine might
be affected by humidity, the interior must be dried and the insulation re-checked.
7- The plasma cutting machine should be protected against tossing around while lifting and protected
against impacts.
8- If the plasma cutting machine is to be stored for a long time, place it in the original box and store in a
dry place.
Adjust the air pressure between
4.5-5 bar.
Shut down the machine and reinstall
the torch tip or electrode.
Shut down the machine and reinstall
the cutting nozzle.
Contact to the service.
Air pressure is too low.
Torch tip or electrode
is not installed properly.
Cutting nozzle is not
installed properly.
Check the voltages of the phases
input in the machine.
Reconnect the phases.
No electric in the line.
PROBLEM
POSSIBLE REASON
SOLUTION
When machine is
started, Torch/Air
Pressure light flashes.
When machine is
started, Torch/Air
Pressure lamp lights on.
Power led lights but
fan and air valve do
not operate.
Main board is faulty.