3.1) Connect state.
Connect state shows the com open or not.
3.2) Com select.
Select which com you will use.
Connect button.
The word on this button will change when the connection state changes. If the word is “Disconnect”,
then click this button, the com will be closed. If the word is “Connect”, then click this button, the com
will be opened.
4) Control command format
If user want to write his own control software, below are data format and baud rate setting.
Com port setting:
Baud Rate:
9600 bps
Data bits:
8 bits
Parity:
None
Stop bits:
1 bit
Flow control:
None
5) RS232 command
command
HEX
feedback
description
cir_0x\r\n
63 69 72 20 30 xx 0D 0A
s1y
Output 1 select input 1~8
“x” : indicate the input port, range
from 0~7.
“y” : indicate the input port, range
from 1~8.
cir_1x\r\n
63 69 72 20 31 xx 0D 0A
s2y
Output 2 select input 1~8
“x” : indicate the input port, range
from 0~7.
“y” : indicate the input port, range
from 1~8.