ASI MFC2000 Operation Download Page 18

Last update: 2021/12/20 16:41

ms2000_operation

https://asiimaging.com/docs/ms2000_operation

https://asiimaging.com/docs/

Printed on 2022/03/16 04:45

Indoor use only

WARNINGS

Ensure power switch is in the OFF position before

1.

plugging in the power cord.
Do not unplug or plug-in devices / cables when power

2.

is on.
Do not remove the cover; no user serviceable parts are

3.

inside.
For indoor use only.

4.

Keep clear of moving equipment. ASI Stages have

5.

current limits on the motors to prevent excessive
traveler force from doing permanent bodily harm, but
pinches can still be painful.
Protection provided by the equipment may be impaired

6.

if the equipment is used in a manner not specified by
ASI.
In the event of device failure, contact ASI: (541)

7.

461-8181
(800) 706-2284
International: 011-541-461-8181

ms2000

manual

0-10v

1)

If you do not see “Ports (COM & LPT)” when the drivers are installed and the controller connected and
powered up, then the computer may not fully support USB and RS-232. Certain inexpensive laptops
have been observed with this defect. The workaround solution for this problem is to use a Serial Port
PCI Card. Alternately, your computer may work with a Keyspan USA19HS High Speed USB / Serial
Adapter. This device, a cable with two connectors, plugs into your USB port, and the other end is a
serial port connector. With either the Keyspan or the Serial Card, you connect the device to the
controller via a serial null modem cable. A serial null modem cable is furnished with each ASI
controller and widely available at computer stores. Note that if the words “NULL MODEM” are not
stamped on the connectors of a serial cable, it is probably not a null modem cable.

From:

https://asiimaging.com/docs/

 - Applied Scientific Instrumentation

Permanent link:

https://asiimaging.com/docs/ms2000_operation

Last update: 2021/12/20 16:41

Summary of Contents for MFC2000

Page 1: ...ings for the joystick may be programmed and saved in rmware See the JSSPD command Command Encoder Knob The Command Encoder Knob is usually used to control the Z axis stage The relative speed of the kn...

Page 2: ...witch is not used or used for other special purposes LCD Screen Note MS2000 and RM2000 have a 4 line LCD MFC2000 controllers only have a two line LCD The Liquid Crystal Display LCD screen shows the cu...

Page 3: ...ell On the right side is a time clock Some error codes are displayed in place of the clock for a few seconds after they occur Mode 3 SW 1 2 UP Dual Display with Status Line Shown 4 line version 2 line...

Page 4: ...til the axis reaches target to the accuracy speci ed by the PC error variable Should the stage drift further from the current target by more than the E drift error variable the motors will re engage a...

Page 5: ...port is controlled by a second UART on the microcontroller As a default it is con gured as a pass though so serial tra c sent to the controller from the PC is echoed directly on the OUT port Special f...

Page 6: ...ces Switches 1 2 select the LCD screen options Switches 4 and 5 set up the serial baud rate for the RS 232 and USB interfaces Switches 3 6 select between linear and rotary encoders for the XY and Z ax...

Page 7: ...ten there are special rmware modules that are included to provide custom functionality The BUILD X BU X command lists the rmware basic build avor and all of the special rmware modules that are include...

Page 8: ...the current stage position will be lost Upon loss of power the controller will send the character O out the serial port After successfully saving positions the controller will send the character K Sav...

Page 9: ...near encoded stages and especially when a second axis remains in motion after one axis has nished moving Turning the drivers o and using error threshold hysteresis means that most of the time there is...

Page 10: ...teger multiple of the slowest speed Be aware that at the very slowest speeds the condition and cleanliness of the stage and the calibration of the analog stage driver circuitry can have a dramatic e e...

Page 11: ...ontroller to detect an error condition The motors are immediately turned o and the o ending axis is disabled If this happens a D character is displayed as the status indicator on the LCD display The u...

Page 12: ...some examples of the con gurations settings that can be changed See the CCA command for details The con guration ags are usually only changed when the controller is rst set up for a particular set of...

Page 13: ...king memory and clears the data from the Saved Position nonvolatile memory locations to ready those storage locations for when power is again shut o If the controller is RESET without turning o the po...

Page 14: ...tems On systems with a PIEZO axis this is the controled voltage when a commanded move to the PIEZO usually Z axis is made DAC_OUT with WRDAC command provides external analog output 6 TTL IN1 INPUT Aux...

Page 15: ...ted 9 N C Not Connected 10 X Lim U X Upper Limit 11 5V 5V X limits 12 Y Lim U Y Upper Limit 13 5V 5V Y limits 14 X Mot X Motor 15 5V 5V X encoder 16 X Enc Ch B X Encoder Channel B 17 Y Mot Y Motor 18...

Page 16: ...TION 2 R In Receive 3 T Out Transmit 5 GND Signal Ground 1 4 6 9 N C Not Connected RS 232 Serial Out DB 9M Connector PIN SIGNAL INFORMATION 2 T Out Transmit 3 R In Receive 5 GND Signal Ground 1 4 6 9...

Page 17: ...Connected IN BNC optional PIN SIGNAL INFORMATION Center TTL IN VIH 3 2V VIL 1 3V Outer GND Signal Ground OUT BNC optional TTL PIN SIGNAL INFORMATION Center TTL OUT VOH 4 4V VOL 0 1V IO Max 50mA Outer...

Page 18: ...0 10v 1 If you do not see Ports COM LPT when the drivers are installed and the controller connected and powered up then the computer may not fully support USB and RS 232 Certain inexpensive laptops ha...