General safety information

                                Disconnect power at the
service breaker before installing or servicing. 

 

                                

                                This product is intended 
for installation by a qualified service person. 
Use AWG NO. 12 solid conductor for wiring.

                                All units must be supplied 
with a 3-wire service. The ground wire must 
be connected to the dryer's backplate. 

                                Failure to properly ground 
unit could result in severe electrical shock 
and/or death.

Installation Kit Included (find in carton)

1. Wall box Installation Screws (M5x25 Philips pan head self threading) x 4 pcs           
2. Nylon bushing x 1 pc
3. Crimp-on terminal wire tip x 3 pcs                  

Service Tool Included (with installation kit)

Security hex 

 4 mm x 1 pc (5/32" pin-hex will work if tool is lost)

wrench

Please unpack the unit and check the quantity of the above tool and kit. 

Operation

                     See Installation Guide (IG) on pages 2 & 3

Shake excess water from hands. 
Place hands under the nozzle and dryer automatically starts operation. LED in sensor array shines 
blue light during operation to guide user to optimal hand placement for fastest drying time.  
Rub hands lightly and rapidly under the nozzle.
Dryer stops when hands are removed from 
sensor zone or if maximum time is reached.
Sensor Adjustment Control.
See sensor range adjustment section on page 5

DO NOT OVER TURN!

Recommended mounting heights

- from top edge of hand chamber above finished floor (AFF)

(50") 

Men
Women
Children 4-7 years
Children 8-10 years
Children 11-13 years
Children 14-16 years
Handicaped

1270 mm

(47") 

1194 mm

(35") 

889 mm

(39") 

991 mm

(43") 

1092 mm

(47") 

1194 mm

(40") 

1016 mm

Summary of Contents for Turbo-Tuff 10-0135-2

Page 1: ...pping Weight Unit Size PERFORMANCE DATA 220 240VAC 50 60Hz 4 2A 1 0KW 55 C when ambient Temp 25 C MAX adjustable by owner MIN 69 2dB A to 69 3dB A MAX 2m adjustable by owner IP24 500W 22000 29000rpm adjustable brush type dual ball bearings Auto resetting thermostat turns unit off at 95 C Range adjustable by owner 275 500 W Auto resetting thermostat turns heater element off at 85 C resets at 75 C t...

Page 2: ...n relief clamp on chassis Clamp cable prep ends of wires and insert correct wires into terminal block at locations L N G Using a small flat blade screwdriver ensure each wire is properly secured with terminal block top lock screws Connections see fig 6 refer to Circuit Diagram and see Note B A Connect the live wire colored Brown Red or Black to the terminal block marked L B Connect the neutral wir...

Page 3: ... asijdmacdonald com au 1 2 3 Bushing Wall 8 RWO STUB CABLE DETAIL OF BUSHING IN STEP 4 TO PUSH INTO KO A B A 4 A REMOVE KO PUSH BUSHING INTO HOLE B C WIRE GOES IN D 5 7 A B A B B A A DETAIL A FOR STEP 5 3 16 5 Item 36 NOTE B OPTIONAL TERMINALS FOR STRANDED WIRE 14 16 GA FOR STEP 6 HOOK TYP A B 6 SEE CIRCUIT DIAGRAM IN OWNER MANUAL 1207311534 SLACK CABLE SEE NOTE B ...

Page 4: ...l wire tip x 3 pcs Service Tool Included with installation kit Security hex 4 mm x 1 pc 5 32 pin hex will work if tool is lost wrench Please unpack the unit and check the quantity of the above tool and kit Operation See Installation Guide IG on pages 2 3 Shake excess water from hands Place hands under the nozzle and dryer automatically starts operation LED in sensor array shines blue light during ...

Page 5: ...t Board Module MO2 HE2 N MO1 HE1 L Transistor Power Switch VR G N L Thermostat Red 110 120V Black G Y Blue Motor With Thermal Switch 2A Heater With Thermo fuse FOR SENSOR White 110 120V Sensor module VR FOR SPEED Black Brown 5 www asijdmacdonald com au VR FOR AIR SPEED Warm a r speed adjustment i 1 Switch off the power loosen the cover screws and remove the cover 2 Use small Philips head screwdriv...

Page 6: ... asijdmacdonald com au www asijdmacdonald com au 1800 023 441 ASI JD MacDonald Pty Ltd Symptom Corrective Actions for In Service Failures If the dryer will not run The IR sensor only sees close range objects Ensure that there is no obstruction on or in front of the IR sensor Clean any dirt or debris off the sensor lens Check VR for sensor range setting If problem persists disconnect the power and ...

Page 7: ...Sensor module Label Circuit Diagram Cover Stainless steel Satin 20 21 22 23 24 25 26 27 28 29 30 31 32 33 36 37 38 39 40 Key Part A0393 A0274 A0363 A0364 A0124 A0276 A0268 A0242 A0277 Description Qty 1 1 2 1 2 8 2 1 4 2 1 1 1 1 3 1 2 4 2 Rating label 10 0135 2 Dry hand chamber Security hex screw Recessed box Screw M4x10 philips pan head Self threading screw M4x10 philips pan head Screw M3x16 phili...

Page 8: ...ly Diagram Tool Req d Security hex wrench Item 31 Tools Req d Not provided Crimp tool Philips 1 2 Wire cutter Flat blade 3 64 THK 1 1 36 Optional Terminals Provided in kit Use AWG 16 14 MAX 1 2 5 8 9 10 11 13 12 14 15 16 17 18 19 21 22 24 23 24 25 25 25 26 27 28 29 20 28 37 SEE INSTALLATION STEPS Typical Location 1 of 5 Positions Provided in kit Provided in kit 38 39 3 4 6 7 32 33 40 1 8 DIA Ø3 ...

Reviews: