background image

Operating Manual - NE Multi Channel Power Amplifier

12

5. PROTEA

ne

 SOFTWARE

Protea

ne

 software offers a comprehensive suite of tools for controlling Ashly NE multichannel amplifiers. The standard amplifiers 

allow for Ethernet control and monitoring of power functions, mute, and preset control. With the DSP option installed, software 

control and monitoring of audio functions can be custom configured on a per channel basis, as well as through linked channels. 

More in depth discussion of software features can be found in the Protea

ne 

software online help.

The base amplifier interface includes a main control surface, password protected security functions, and network property 

management. Link Group Configuration and Power On Delay* can be set up under the Device Options menu tab. In addition, 

provisions for implementing DSP functions, AES/EBU Inputs, and network audio inputs are available, presuming the neces

-

sary hardware options have been installed in the amplifier. Protea

ne

 software will auto-detect any installed hardware options and 

display the resulting menu items once it recognizes the amplifier on the network. 

*

Note

 - 

Power On Delay does not work when standby mode is activated via contact closure.

Link Group Configuration 

- Linking allows the controls for multiple DSP function blocks to track each other. For example, if 

two different graphic equalizer blocks are assigned to a link group, any change made to a control within either of the equalizers 

will result in an identical change to the other. Blocks may be linked across channels.

Each device will support up to 16 link groups. DSP function blocks can be individually assigned to these link groups. Once 

assigned to a group, all similar functions within that group will track parameter changes. More than one function type may be 

assigned to a group. Each link group can be assigned a name by the user, and can also be assigned a color for easy identification. 

For further details about linking, see the software online help.

Preset Options

 - The preset options menu allows amplifier setups to be saved to or recalled from an amplifier or a computer. 

File 

presets

 are the complete amplifier and software settings, whereas 

device presets

 are limited to commonly used functions.

Sub Presets

 - Sub Presets are user defined groups of DSP functions within one channel or across multiple channels. Sub Presets 

allow the user to instantly recall a pre-determined set of DSP parameters to quickly address changing environmental conditions, 

without the risk of making undesirable or irrecoverable system changes.

The Amplifier Control Surface Tab

The control surface tab is the main software interface for the amplifier. Key features of this window include:
1) Channel and Offset Link Group Faders - The main level control provides up to 40dB of analog input attenuation. More than 

40dB of cumulative attenuation causes the channel to mute. If a channel has been assigned to an offset link group, a colored 

triangular marker appears on the left side of the fader graticule for secondary level control of all channels in that group. The 

main level control faders can not be linked to a group.
2) Mute button - This mutes the input channel
3) Polarity button - This inverts the phase of the input channel
4) Offset link group - Up to 16 groups are available for the purpose of linking similar function parameters across multiple chan

-

nels. In addition to the control surface secondary level control (not the main fader), most DSP functions have a link group check 

box in their work window to assign a specific parameter to one of the eight link groups if desired. Link groups can be renamed 

by clicking on any group name and entering the new name then pressing <enter> on the keyboard.
5) Attenuators - These two dials indicate the physical position of hardware controls on either the amp front panel or remote 

DC level control (if present). Note that these will display the position of attenuators even when they are disabled by software.
6) Total Attenuation - This indicates the total amount of attenuation being applied to the channel. This is the sum of the follow

-

ing attenuators: main fader, offset link group attenuation, front panel and remote attenuators.
7) Meters - Input and Output meters display the real time activity per channel, in dB below rated output. Also, the amplifier’s 

operating temperature and output current are shown. Output current shows that the amplifier channel is actually delivering 

output to a connected speaker load.

Summary of Contents for Protea NE4250

Page 1: ...5 872 0739 www ashly com 2016 by Ashly Audio Corporation All rights reserved worldwide All Trademarks referred to herein are the property of their respective owners ne4250 ne4250 25 ne4250 70 ne4250 10 Operating Manual Network Enabled Multi Channel Power Amplifiers ne8250 ne8250 25 ne8250 70 ne8250 10 ...

Page 2: ... to rain or moisture does not operate normally or has been dropped 1 Lisez ces instructions 2 Conservez ces instructions 3 Observez les avertissements 4 Suivez ces instructions 5 Pour réduire le risque de feu ou la décharge électrique ne pas exposer cet appareil pour pleuvoir ou l humidité 6 Ne pas utiliser l appareil près de l eau 7 Le nettoyer à l aide d un tissus sec 8 Ne pas bloquer les ouvert...

Page 3: ...ote Standby 8 Preset Recall 8 WR 1 Remote Level Control 9 WR 2 Remote Preset Recall Switch 9 WR 1 5 Remote Level Control and Preset Switch 9 RD 8C and RW 8C Remote Fader Control 10 WR 5 Remote Programmable Button Control 10 neWR 5 Networked Remote Programmable Button Control 11 FR 8 and FR 16 Networked Programmable Fader Control 11 Ashly Remote App for iPad 11 5 Proteane SOFTWARE 12 Overview 12 Am...

Page 4: ...conditions 1 This device may not cause harmful interference 2 This device must accept any interference received including interference that may cause undesired operation 2 UNPACKING As a part of our system of quality control every Ashly product is carefully inspected before leaving the factory to ensure flaw less appearance After unpacking please inspect for any physical damage Save the shipping c...

Page 5: ...the amplifier Using AES3 2 channels of digital audio are sent over a single mic cable maintaining a completely digital signal path until just before the power amplification stage 48kHz 96kHz data rates are supported AES3 can be installed with or without DSP 3 Network Audio Dante or CobraNet network audio modules can be factory installed with or without installed DSP Note that amplifiers without DS...

Page 6: ...nfirms that the amplifier output is delivered to a speaker load 9 Channel Attenuators These control the input signal level to the amplifier They can be disabled from software 10 Factory Reset To reset all internal configurations including passwords back to their original factory settings press and hold this recessed front panel momentary switch during power up until all channel LEDs are lit Upon r...

Page 7: ...c application setup and settings on the amplifier When setting up and testing your system please take special care to double check all connections and settings Refer to the specifications section of this manual for spe cific input output and other figures Constant Voltage Models 25V 70V and 100V and High Pass Filters Amplifiers that are factory configured as constant voltage models 25V 70V or 100V...

Page 8: ...fter the amp is unplugged from AC Preset Recall The preset recall connections on the back panel allow different presets to be loaded from amplifier memory when one of the contacts is closed to the provided ground pin Device presets are configured from software and can include gain settings mute status polarity and DSP functions if the amp has DSP installed The NE amplifier stores up to 35 internal...

Page 9: ... to the wiper Do not connect the WR 1 remote level control ground to any other external grounds WR 2 Remote Preset Recall Switches The WR 2 shownatright allowsselectionofoneoffourpresetsviainterlock ingpushbuttonswitches Eachpushbuttonswitchcanbeconnected to a Preset Recall Pin on the back panel of the amplifier The ter minal numbers correspond to the first 4 device presets stored in the amplifier...

Page 10: ...ora cover plate not included can be purchased at hardware stores to cover the WR 5 electrical box and satisfy the aesthetic needs of the installation The WR 5 is phantom powered from the amplifier Up to four different WR 5 remotes can be phantom powered from one amplifer and more can be added by purchasing an Ashly RPS 18 remote power supply WR 5 buttons are programmed from software after the WR 5...

Page 11: ...meters such as gain or preset number and are indicated by the LED display Without DSP installed in the amplifier neWR 5 functions are limited to preset recall and mute Note To use the neWR 5 as a remote level control a ne WR 5 Remote Gain tool must be placed in one of the DSP processing blocks of the channels s There is also a hard wired Lock Out feature on the neWR 5 where the closing of a switch...

Page 12: ...mplete amplifier and software settings whereas device presets are limited to commonly used functions Sub Presets Sub Presets are user defined groups of DSP functions within one channel or across multiple channels Sub Presets allow the user to instantly recall a pre determined set of DSP parameters to quickly address changing environmental conditions without the risk of making undesirable or irreco...

Page 13: ...ers FIR filter outputs only 4 Crossover functions Four Way Three Way and Two Way Crossovers are available on outputs only HPF and LPF filters are available on both inputs and outputs 5 Delay Speaker Delay at 48kHz sampling rate is 21mS and Delay is 682mS At 96kHz 10 6mS and 341ms 6 Metering 60dBu to 20dBu display 7 Signal Generator Pink noise White Noise Sine Wave from 20Hz to 12kHz Extensive onli...

Page 14: ... ohm load 10dB below rated power 0 5 Distortion THD N typical 8 ohm load 10dB below rated power 20Hz 20kHz 0 5 Frequency Response 20Hz 20kHz 1dB Damping Factor 8 ohm load 1kHz 250 Input Impedance 20K Ohm balanced Maximum Input Level 21dB Cooling temperature controlled fan cool air is drawn in from the sides and blown out the front Control Network Standard 100MB Ethernet Front Panel Indicators per ...

Page 15: ...etric Filter Types Parametric Frequency 20 20kHz Level 30dB to 15dB Q Value 0 016oct to 4oct Hi Low Shelf 6 12 dB Frequency 20Hz 20kHz Level 15dB to 15dB All Pass Frequency 20Hz 20kHz Variable Q HP LP Frequency 20Hz 20kHz Q Value 3 047 to 0 267 Notch Bandpass Frequency 20Hz 20kHz Q Value 92 436 to 0 267 Crossover 2 Way 3 Way 4 Way Crossover High Pass Low Pass Filters Filter Types Bessel 12 18 24 4...

Page 16: ...DSP or Network Audio 2 With Protea DSP 3 With Protea DSP and Network Audio or AES3 Input 4 With Network Audio or AES3 Input but Without DSP factory installed DAC converter required Remote Control Options Vary With Configuration DSP is Required for Most Programmable Remote Control Functions Protea NE Software Control Factory Options bypassed if not installed Protea DSP DSP Processing Load Impedance...

Page 17: ...efaced or removed ASHLYAUDIO INC reserves the right to make changes in design or make additions to or improvements upon this product without any obligation to install the same on products previously manufactured Any implied warranties which may arise under the operation of state law shall be effective only for FIVE years from the original date of purchase of the product ASHLY AUDIO INC shall be ob...

Page 18: ...Operating Manual NE Multi Channel Power Amplifier 18 This page intentionally left blank ...

Page 19: ...19 Operating Manual NE Multi Channel Power Amplifier This page intentionally left blank ...

Page 20: ... 585 872 0010 Fax 585 872 0739 Toll Free 800 828 6308 www ashly com Ashly Audio is a division of Jam Industries Ltd 2016 by Ashly Audio Inc All rights reserved worldwide All features specifications and graphical representations are subject to change or improvement without notice Printed in USA r11 0416 ...

Reviews: