INSTALLATION
FLOOR PROTECTOR
This heater must have a non-combustible floor
protector (ember protection) installed beneath it if
the floor is of combustible material. If a floor pad is
used, it should be UL listed or equal. The floor pad or
non-combustible surface should be large enough
to extend under the stove and beyond each side
as indicated. If there is a horizontal run of flue pipe,
there needs to be floor protection under it that
extends two inches beyond either side of the pipe.
REAR
FRONT
SIDE
SIDE
Front
*16” (407 mm)
Sides
8” (204 mm)
Rear
2” (51 mm)
*Canadian Installations
require 18” (457 mm).
CLEARANCES TO COMBUSTIBLES
It is of utmost importance that the clearances to
combustible materials be strictly adhered to during
installation of the stove.
•
Do not place any combustible material within 4’
(1.2m) of the front of the unit.
•
Floor to ceiling height must be at least 7’ (2.13m)
in all cases.
•
The clearance between the flue pipe and a wall
are valid only for vertical walls and for vertical flue
pipe.
• The chimney connector must not pass through
an attic or roof space, closet or similar concealed
space, a floor, or a ceiling.
• For Canadian installations, where passage through
a wall, or partition of combustible construction is
desired, the installation must conform to CAN/
CSA-B365.
•
A flue pipe crossing a combustible wall must have
a minimum clearance of 18” (458 mm).
•
To reduce flue clearances from combustible
materials, contact your local safety department.
D
B
A
C
E
F
E
Single Wall Pipe
Key
in
mm
A
17
432
B
21
534
C
20
508
D
29
737
E
14
356
F
22
559
OUTSIDE COMBUSTION AIR
Your wood stove is approved to be installed with
an outside air intake (4FAK) which is necessary
for a mobile home. This type of installation is
also required in air tight houses and houses with
negative pressure problems. You can purchase this
option through your heater dealer. Make sure to
specify the part number mentioned in this booklet.
Installation instructions are supplied with the air
intake kit. Outside combustion air may be required
if
6
© 2021 United States Stove Company