3
Heating Specifications
Fuel Burn Rate* (lowest setting)
1.5 lbs./hr.
Burn Time (lowest setting)
32 hrs. (approximate)
Hopper Capacity
50 lbs.
Dimensions
Height
32.8 in. (834mm)
Width
21 in. (534mm)
Depth
23.77 in. (604mm)
Weight
145 lbs.
Electrical Specifications
Electrical Rating
120V, 60 Hz, 3.0 Amps
Watts (operational)
180W
Watts (igniter running)
350W
This manual describes the installation and operation of the Ashley
model AP60 pellet stove. This heater meets the 2015 U.S. Environmental
Protection Agency’s crib wood emission limits for wood-heaters sold
after May 15, 2015. Under specific EPA test conditions burning Douglas Fir
dimensional lumber this heater has been shown to deliver heat at a rate
of 8,4763 to 20,700 Btu/hr. This heater achieved a particulate emissions
rate of 1.46 g/hr when tested to method ASTM E 2779 / EPA Method 28R.
FUEL CONSIDERATIONS
Your pellet stove is designed and tested with premium grade pellets that comply with Pellet Fuels Institute (PFI)
standards. You can only burn premium grade pellets in this pellet heater. (Minimum of 40 lbs density per cubic
feet, 1/4” to 5/16” diameter, length no greater than 1.5”, not less than 8,200 BTU/lb, moisture under 8% by weight,
ash under 1% by weight, and salt under 300 parts per million). Pellets that are soft, contain excessive amounts
of loose sawdust, have been, or are wet, will result in reduced performance and may cause damage to your
heater. Store your pellets in a dry place.
DO NOT store the fuel within the installation clearances of the unit or within the space required for refuelling and
ash removal. Doing so could result in a house fire.
Do not over-fire or use volatile fuels or combustibles, doing so may cause a personal and property damage
hazards.
SAFETY AND EPA COMPLIANCE
Your pellet stove has been approved for installation in the USA and Canada. It may also be installed in a
manufactured or mobile home. Your stove is Certified to ASTM E 1509, 2012, and Certified to ULC S627, 2000,
and(UM) 84-HUD.
* Pellet size may effect the actual rate of fuel feed and burn times. Fuel feed rates may vary by as much as
20%. Use PFI listed fuel for best results.
Specifications
WARNING:
It is against federal regulations to operate this wood heater in a manner inconsistent with the
operating instructions in the owner’s manual.
Report No. 18-409