16
© 2022 United States Stove Company
is present vacuumed clean as the ash or dust can
impede the fans performance. It is also possible
that creosote may accumulate in the exhaust fan
therefore, this must be brushed clean. The exhaust
fan can be found behind the left side panel (facing
the front of the heater), the circulation fan can
be found behind the right side panel. To access
the igniter, remove the air inlet tube and cover (2
screws). The auger motor is located in the center
rear of the unit. Note: When cleaning, take care not
to damage the fan blades.
If a vacuum is used to clean your stove, we suggest
using the AV15E AshVac vacuum. The AV15E AshVac
is designed for ash removal. Some regular vacuum
cleaner (i.e. shop vacs) may leak ash into the room.
DO NOT VACUUM HOT ASH.
WARNING:
FAILURE TO PROPERLY MAINTENANCE
THE CLEAN OUTS WILL RESULT IN POOR
PERFORMANCE OF THIS STOVE.
Clean-Out Plates
OPERATION INSTRUCTIONS