DANGER

 

Before installation, read the following instructions carefully. 

Failure to follow instruction and safety information could 

cause serious bodily injury, death and/or property damage. 

Each Ashland Pump is individually factory tested to ensure 

proper performance. Closely following these instructions 

will eliminate potential operating problems assuring years 

of trouble-free service.
Most accidents can be avoided by using common sense.
IMPORTANT - Ashland Pump is not responsible for 

losses, injury or death resulting from failure to observe 

these safety precautions, misuse, abuse or misapplica-

tion of pumps or equipment.
 

 

All returned products must  

 

 

 

be cleaned, sanitized, or    

 

 

decontaminated prior to shipment, to  

 

 

insure employees will not be exposed to  

 

 

health hazards in handling said materials.    

 

All applicable laws and regulations shall apply.

   

Bronze/brass fitted pumps may  

   

 

contain lead levels higher than 

considered safe for potable water systems. Government 

agencies have determined that leaded copper alloys 

should not be used in potable water applications. 
   

Installation, wiring, and junction 

   

connections must be in accord-   

ance with the National Electric Code and all applicable 

state and local codes. Requirements may vary depend-

ing on usage and location. 
   

Installation and servicing is to be  

 

   

conducted by qualified personnel only.

  

Rotating machinery, amputation  

 

 

 

or severe lacerations can result.    

 

 

Keep clear of suction and discharge  

 

 

openings. DO NOT insert fingers into 

 

 

pump with power connected.

 

 

 

Always wear eye protection when    

 

working on pumps. Do not wear loose clothing that 

may become entangled in moving parts. 
 

 

Pumps build up heat and    

 

 

 

pressure during operation.  

Allow time for pumps to cool before handling 

or servicing. 
   Hazardous Voltage can shock,    

 

 

burn or cause death. This pump is  

 

not intended for use in swimming pools or    

 

water installations where human contact with  

 

pumped fluid is possible. 

 

 

Risk of electrical shock. To  

 

 

 

reduce risk of electrical shock,    

 

always disconnect pump from source  

 

 

before handling. Lock out power & tag.

 

 

WARNING 

 

Do Not use these pumps in water  

 

over 145°F. Do not exceed manu-

factures recommended maximum performance, as this 

could cause the motor to overheat.

WARNING 

   

WARNING 

WARNING 

WARNING 

DANGER

 

DANGER

 

DANGER

 

 

 

These pumps are NOT to be  

 

 

 

installed in locations classified  

 

 

as hazardous in accordance with the   

 

 

National Electric Code, ANSI/NFPA 70.

WARNING 

 

Pumps often handle materials which  

 

could cause illness or disease. Wear 

adequate protective clothing when working on a used 

pump or piping. Never enter a basin after it has been 

used.

WARNING 

 

Do not introduce into any sewer,  

 

either directly, or through a kitchen 

waste disposal unit or toilet: Seafood Shells, Aquarium 

Gravel, Cat Litter, Plastic Objects, Sanitary Napkins or 

Tampons, Diapers, Rags, Disposable Wipes or Cloth, 

Medications, Flammable Material, Oil or Grease, Strong 

Chemicals, Gasoline. 

DANGER

 

DANGER

 

 

 

Do not lift, carry or hang pump by  

 

 

 

the electrical cables. Damage to  

               the electrical cables can cause shock, burns or      

               death. Never handle connected power cords with wet   

               hands. Use appropriate lifting device.

DANGER

 

 

 

Failure to permanently ground the   

 

 

pump, motor and controls before    

 

connecting to power can cause shock, burns  

 

or death.

DANGER

 

 Make sure lifting handles are securely  

 

fastened each time before lifting.

CAUTION 

•   Operation against a closed discharge valve will cause

  premature bearing and seal failure on any pump.  
•   Any wiring of pumps should be performed by a  

 

  qualified electrician.
•  Cable should be protected at all times to avoid  

 

  punctures, cuts, bruises, and abrasions-inspect  

 

 frequently.
•  Never handle connected power cords with wet hands.
•   Never let cords or plugs lie in water outside the sump    

 pit.
•   These pumps are offered in a three phase and single  

  phase wiring configuration. Voltages will vary

  according to the application and can be seen in the    

  tables in this manual.

 

Solids Handling Pumps

Models: 3ANC300/500/750,

4ANC2500/3000/4000/5000/6000,

6ANC1000/1500/2000/3000/4000/5000/6000,

8ANC5000/6000 General Safety Information

Summary of Contents for 3ANC300

Page 1: ...s situation which if not avoided WILL result in death or serious injury Caution indicates a potentially hazardous situation which if not avoided MAY result in minor or moderate injury MARKS AND MEANING WARNING CAUTION DANGER Thank you for purchasing this pump Take the time to read the instructions carefully before using this product We strongly recommend that you keep this instruction manual in a ...

Page 2: ... of electrical shock To reduce risk of electrical shock always disconnect pump from source before handling Lock out power tag WARNING Do Not use these pumps in water over 145 F Do not exceed manu factures recommended maximum performance as this could cause the motor to overheat WARNING WARNING WARNING WARNING DANGER DANGER DANGER These pumps are NOT to be installed in locations classified as hazar...

Page 3: ... N A 4ANC3000M4 30 60 460 3 1750 38 G SOOW 6AWG 1 08 N A N A N A 4ANC4000M4 40 60 460 3 1750 50 G SOOW 6AWG 1 08 N A N A N A 4ANC5000M4 50 60 460 3 1750 60 G SOOW 6AWG 1 08 N A N A N A 4ANC6000M4 60 60 460 3 1750 80 G SOOW 6AWG 1 08 N A N A N A 4ANC2500M3 25 60 230 3 1750 66 G SOOW 6AWG 1 08 N A N A N A 4ANC2500M4 25 60 460 3 1750 33 G SOOW 6AWG 1 08 N A N A N A 6ANC1000M3 10 60 230 3 1750 28 H SO...

Page 4: ...5 3ANC500 33 9 4 0 12 8 15 7 5 8 5 3ANC750 33 9 4 0 12 8 15 7 5 8 5 4ANC2500 46 5 1 21 25 9 9 0 16 5 4ANC3000 46 5 1 21 25 9 9 0 16 5 4ANC4000 46 5 1 21 25 9 9 0 16 5 4ANC5000 54 3 5 1 25 9 26 9 0 16 5 4ANC6000 54 3 5 1 25 9 26 9 0 16 5 6ANC1000 43 3 8 9 19 4 24 6 11 14 8 6ANC1500 43 3 8 9 19 4 24 6 11 14 8 6ANC2000 45 6 8 9 19 4 24 6 11 14 8 6ANC3000 48 8 9 19 4 24 6 11 14 8 6ANC4000 51 7 10 7 23...

Page 5: ...5 Solids Handling Pumps Models 3ANC300 500 750 4ANC2500 3000 4000 Performance ...

Page 6: ...6 Solids Handling Pumps Models 4ANC500 6000 and 6ANC1000 1500 2000 Performance HEAD FEET GALLONS PER MINUTE FLOW 4ANC6000 4ANC6000 4ANC6000 4ANC5000 4ANC5000 4ANC5000 ...

Page 7: ...7 Solids Handling Pumps Models 6ANC3000 4000 5000 6000 Performance ...

Page 8: ...8 Solids Handling Pumps Models 8ANC5000 6000 Performance ...

Page 9: ... a minimum of 3 inches to a maximum of 4 5 inches Submergence The pump should always be operated in the submerged condition See Minimum submergence and pump clear ance levels below in figure 1 WARNING Installation The sump or basin shall be sealed and vented in accor dance with local plumbing codes This pump is designed to pump domestic wastewater nonexplosive and noncorrosive liquids and shall NO...

Page 10: ...the numbers on the pumps identification plate and record at the end of this manual for future reference Discharge Piping Install discharge piping or hose assembly to the pump Dis charge piping should be as short as possible and sized no smaller than the pump discharge Do not reduce the dis charge pipe size below that which is provided on the pump Both a check valve and a shut off valve are recomme...

Page 11: ...tation can result in poor pump performance and can damage the motor and or pump Check rotation by momen tarily applying power and observe the kickback Kickback should always be in a counter clockwise direction as viewed from motor end or opposite to impeller rotation Incorrect rotation for Single Phase pumps is unlikely If the rotation is incorrect contact factory 3 Name Plate Record the informati...

Page 12: ... 7 5 28 3ANC500M4 5 3 7 5 28 3ANC750M3 7 5 3 7 5 28 3ANC750M4 7 5 3 7 5 25 4ANC2500M4 25 10 57 31 91 4ANC3000M4 30 10 57 31 91 4ANC4000M4 40 10 57 31 91 4ANC5000M4 50 10 57 66 57 4ANC6000M4 60 10 57 66 57 6ANC1000M3 10 9 51 24 3 6ANC1000M4 10 9 51 24 3 6ANC1500M3 15 9 51 24 3 6ANC1500M4 15 9 51 24 3 6ANC2000M4 20 10 57 24 3 6ANC3000M4 30 10 57 31 91 6ANC4000M4 40 10 57 31 91 6ANC5000M4 50 10 57 66...

Page 13: ...TSIDE VALVE BOX GATE VALVE HINGED ACCESS DOOR ALUM OR STEEL OPT JUNCTION BOX MUST BE USED IF CONTROL BOX IS OFFSET FROM BASIN INLET AS REQ D TOP RAIL SUPPORT BELOW FROST LINE CHECK VALVE DISCHARGE PIPING 3 4 GUIDE RAILS MUST BE PLUMB DISCH AND RAIL SUPPORT CASTING LIFTING CHAIN FIGURE 3 Solids Handling Pumps Models 3ANC300 500 750 4ANC2500 3000 4000 5000 6000 6ANC1000 1500 2000 3000 4000 5000 6000...

Page 14: ...l be included with control panel 3 All wires should be checked for shorts to ground with an ohmmeter or megger after the connections are made This is IMPORTANT as one grounded wire can cause failure of the pump control panel or personal injury Solids Handling Pumps Models 3ANC300 500 750 4ANC2500 3000 4000 5000 6000 6ANC1000 1500 2000 3000 4000 5000 6000 8ANC5000 6000 Wiring Wiring Diagram Dual Si...

Page 15: ...d overload on the motor 2 Impeller may be rubbing on wear ring due to bent shaft or misalignment 3 Pump may be operating too close to shut off 1 Lower control switch may be set too high 2 Trash and grease may have accumulated around floats causing pump to operate erratically 1 Replace the lower seal 1 Check impeller for freedom of operation security and condition Clean impeller cavity and inlet of...

Page 16: ...ndling Pumps Models 3ANC300M3 35 3ANC500M3 35 and 3ANC750M3 35 Repair Parts 32 41 P1 P2 P3 P13 18 12 39 30 P4 36 29 35 38 5 11 6 27 40 14 28 P14 4 10 1 P15 24 19 26 34 21 17 48 7 25 16 1 3 P5 33 42 8 20 37 9 P7 P6 ...

Page 17: ...LOWER BEARING 1BA7620626 1BA7620727 1BA7620727 1 14 TRU ARC LOCK 1CT914003 1CT9141251 1CT9141251 1 16 THREADED CONNECTOR 1COE2214R0 1COE2214R0 1COE2214R0 10 18 WEDGE 1CU10100W1 3CU8021208 3CU8021208 1 19 WEDGE 3CU4026893 3CU4021067 3CU4021067 1 20 WIRE PASS PACKAGING 1EPN000A70 1EPNOOO176 1EPNOOO176 1 21 STATOR 1ESE020404 1ESE050404 1ESE050404 1 24 SCREW SET 1PRR40204L0 2 25 SPARK PLUG SENSOR 3BU0...

Page 18: ...18 Solids Handling Pumps Models 4ANC2500M4 35 4ANC3000M4 35 Repair Parts ...

Page 19: ...9141759 SNAP RING 4 4 1COE2214R0 THREADED CONNECTOR 440V 16 6 1COC0016Z9 BUTT CONNECTOR 17 2 1EPN000176 WIRE PASS THROUGH GASKET 18 16 1TO40410E6 HEX HEAD CAP SCREW 19 2 1RO40615P0 IMPELLER WASHER 20 1 1TA0060604 CONNECTIONS TABLET 21 2 1TDE558501 ELECTRICAL TERMNIAL 22 3 1TE0011003 THERMOSTAT 23 1 1TO83M02G5 FILLISTER HEAD SCREW 24 2 1TO83M06G1 FILLISTER HEAD SCREW 25 1 1TO40610E9 HEX HEAD CAP SC...

Page 20: ...20 Solids Handling Pumps Models 4ANC4000M4 35 Repair Parts ...

Page 21: ...3BU0030203 MOISTURE SENSOR 13 1 1CT9142504 SNAP RING 16 6 1COC0016Z9 BUTT CONNECTOR 17 2 1EPN000176 WIRE PASS THROUGH GASKET 18 16 1TO40312E8 HEX HEAD CAP SCREW 19 1 3RO4L30006 IMPELLER WASHER 20 1 9BD1643226 CONNECTION BLOCK 21 2 1TDE558501 ELECTRICAL TERMNIAL 23 1 1TO83M04G8 FILLISTER HEAD SCREW 24 2 1TO83M06G1 FILLISTER HEAD SCREW 25 1 1TO40510E8 HEX HEAD CAP SCREW 26 2 1TO40712E4 HEX HEAD CAP ...

Page 22: ...22 Solids Handling Pumps Models 4ANC5000M4 35 4ANC6000M4 35 Repair Parts ...

Page 23: ...NAP RING 13 1 1CT9142504 1 1CT9142504 SNAP RING 15 4 1COCA416A1 4 1COCA416A1 THREADED CONNECTOR 17 1 1ESE400404 1 1ESE400404 STATOR 18 1 1EPN000176 1 1EPN000176 WIRE PASS THROUGH GASKET 19 2 1PR40204L0 2 1PR40204L0 SET SCREW 20 1 1PR40304L2 1 1PR40304L2 SET SCREW 21 1 1SEE200017 1 1SEE200017 UPPER SEAL 22 1 9BD1643226 1 9BD1643226 CONNECTION BLOCK 23 5 1TMB02NP00 5 1TMB02NP00 MALE PLUG 24 2 1TDE55...

Page 24: ...o DESCRIPTION P1 1 3DTFL10004 1 3DTFL20005 CORD CAP 35 P2 1 3TAFL10001 1 3TAFL20002 INTERMEDIATE CORD CAP P3 1 3CMFL10GP0 1 3CMFL15GP0 MOTOR HOUSING P4 1 3CAFL10005 1 3CAFL20153 BEARING HOUSING P5 1 3TCFL10007 1 3TCFL10007 SEAL PLATE 1 3IMFL10157 1 3IMFL15516 IMPELLER P6 1 3IMFL10157 1 3IMFL20158 1 3IMFL15516 1 P7 1 3CCFL100G0 1 3CCFL200G2 VOLUTE CASE ...

Page 25: ...20904 16 2 3BU0030203 2 3BU0030203 MOISTURE SENSOR 18 SNAP RING 19 1 1CT9141759 1 1CT9141759 SNAP RING 20 7 1CNN190009 7 1CNN190009 NYLON BELT 21 4 1COCA416A1 4 1COCA416A1 THREADED CONNECTOR 23 1 3CU8021208 1 3CU8039844 KEY 24 1 3CU4031772 1 3CU4031772 KEY 25 2 1EPN000176 2 1EPN000176 WIRE PASS PACKING 26 1 1EPN0006P9 1 1EPN0006P9 GASKET 27 1 1ESE100404 1 1ESE150405 STATOR 31 4 1TO45M08E8 4 1TO403...

Page 26: ...26 Solids Handling Pumps Models 6ANC3000M4 35 Repair Parts ...

Page 27: ...1 1BA7330923 LOWER BEARING 1BA7330907 15 1 1BA7620920 UPPER BEARING 1BA7620904 16 2 3BU0030203 MOISTURE SENSOR 18 1 1CT9141775 SNAP RING 19 1 1CT9141759 SNAP RING MODEL QTY PART No DESCRIPTION 21 4 1COCA416A1 THREADED CONNECTOR 23 1 3CU8039844 KEY 24 1 3CU4031772 KEY 25 1 1EPN000176 WIRE PASS PACKING 27 1 1ESE200404 STATOR 31 4 1TO40308E4 HEX HEAD CAP SCREW 32 1 1RO40615P0 F LAT WASHER 33 8 1RO406...

Page 28: ...28 Solids Handling Pumps Models 6ANC4000M4 35 6ANC5000M4 35 and 6ANC6000M4 35 Repair Parts ...

Page 29: ... 1CT9142504 1 1CT9142504 1 1CT9142504 SNAP RING 17 4 1COE2214R0 4 1COE2214R0 4 1COE2214R0 THREAD CONNECTOR 18 6 1COC0016Z9 6 1COC0016Z9 6 1COC0016Z9 BUTT CONNECTOR 19 1 3CU8032552 1 3CU8051961 1 3CU8051961 KEY 20 1 3CU4031696 1 3CU4031696 1 3CU4031696 KEY 21 1 1EPN000176 1 1EPN000176 1 1EPN000176 WIRE PASS THROUGH GASKET 22 1 IESE400404 1 IESE400404 1 IESE400404 STATOR 24 2 1PR40204L0 2 1PR40204L0...

Page 30: ...30 Solids Handling Pumps Models 8ANC5000M4 35 and 8ANC6000M4 35 Repair Parts ...

Page 31: ...SOR 17 2 1PR40204L0 KEY 18 1 1CT9512759 SNAP RING 19 1 1CT9142504 SNAP RING 21 4 1COCA416A1 THREADED CONNECTOR 22 6 1COC0016Z9 CONNECTOR CAP 23 1 3CU8051961 KEY 24 1 3CU4031696 KEY 25 1 1EPN000176 WIRE PASS PACKING 26 1 1EPN0008P2 GASKET 27 1 1ESE400404 STATOR 31 2 1TDE558501 NAKED FEMALE ELECTRIC TERMINAL 32 1 IMPELLER WASHER 34 1 1SEE200017 UPPER SEAL MODEL35 QTY PART No DESCRIPTION 35 LOWER SEA...

Page 32: ...M4 25 10 57 31 91 4ANC3000M4 30 10 57 31 91 4ANC4000M4 40 10 57 31 91 4ANC5000M4 50 10 57 66 57 4ANC6000M4 60 10 57 66 57 6ANC1000M3 10 9 51 24 3 6ANC1000M4 10 9 51 24 3 6ANC1500M3 15 9 51 24 3 6ANC1500M4 15 9 51 24 3 6ANC2000M4 20 10 57 24 3 6ANC3000M4 30 10 57 31 91 6ANC4000M4 40 10 57 31 91 6ANC5000M4 50 10 57 66 57 6ANC6000M4 60 10 57 66 57 8ANC5000M4 50 10 57 66 57 8ANC6000M4 60 10 57 66 57 S...

Page 33: ...uct Without limiting the foregoing Ashland Pump specifically disclaims the implied warranties of merchantability and fitness for a particular purpose No warranties or representations at any time made by any representative of Ashland Pump shall vary or expand the provisions of this written Limited Warranty This Limited Warranty contains the purchaser s exclusive remedy for any alleged defect in the...

Reviews: