This device has been tested and found to comply with the

emissions requirements of IEC 60601-1-2:2001-09. These

requirements provide reasonable protection against harmful

electromagnetic interference in a typical medical installation.

However, high levels of radio-frequency (RF) emissions from

electrical devices, such as cellular phones, may disrupt the

performance of this device. To mitigate disruptive

electromagnetic interference, position this device away from

RF transmitters and other sources of electromagnetic energy. 

Classifications in accordance with

UL-60601-1:

- Class II

- Type B Applied Parts

- Type BF Equipment

- Ordinary Protection

- Not suitable for use in the presence of a

flammable anesthetic mixture with air, oxygen,

or nitrous oxide.

Note:

For reliable grounding, connect to receptacle

marked “Hospital Grade”.

To prevent injury to people and damage to property,

please heed relevant warnings and remarks. They

are marked as follows:

WARNING:

Serious injury or death may result if

ignored.

CAUTION:

Damage to property or the

environment may result if ignored.

NOTE:

Important additional information

and hints.

INDICATIONS FOR USE:

The AMC-20 is a mobile self-contained dental system that is

used for endodontic and general dentistry applications. 

RX: FEDERAL LAW RESTRICTS THIS DEVICE TO

SALE BY OR ON THE ORDER OF A DENTIST

TABLE OF CONTENTS:

Introduction  . . . . . . . . . . . . . . . . . . . . . . . . .1

Package Contents  . . . . . . . . . . . . . . . . . . . .1

Safety Precautions  . . . . . . . . . . . . . . . . . . .2

Setting Up the Unit  . . . . . . . . . . . . . . . . . . .3

Figure 12

Cart Front & Side View

 . . . . .5

Figure 13

Cart Back View

 . . . . . . . . . . .6

Figure 14

Cart Back View

 . . . . . . . . . . .7

Operation Functions  . . . . . . . . . . . . . . . . . .8

Optional Equipment Functions  . . . . . . . . .10

Routine Adjustments  . . . . . . . . . . . . . . . . .15

Sterilization & Maintenance  . . . . . . . . .16-18

Packing/Unpacking  Instructions  . . . . . . . .19

Optional Case Packing Instructions  . . . . .20

Troubleshooting . . . . . . . . . . . . . . . . . . . . .21

Specifications  . . . . . . . . . . . . . . . . . . . . . .22

Symbol Definitions . . . . . . . . . . . . . . . . . . .23

Replacement Parts List  . . . . . . . . . . . . . . .24

Warranty  . . . . . . . . . . . . . . . . . . . . . . . . . .25

CONFORMS TO UL STD 60601-1;

CERTIFIED TO CSA STD C22.2 NO. 601.1

Summary of Contents for AMC-20

Page 1: ...AMC 20 Mobile Dental System OPERATION and MAINTENANCE INSTRUCTION MANUAL...

Page 2: ...e Note For reliable grounding connect to receptacle marked Hospital Grade To prevent injury to people and damage to property please heed relevant warnings and remarks They are marked as follows WARNIN...

Page 3: ...n E Type Endodontics Handpiece STANDARD FEATURES Automatic handpiece controls for two pneumatic handpieces Each pneumatic handpiece provides individually controlled water and coolant air 3 way air wat...

Page 4: ...ons concerning disposal of amalgam waste WARNING Never operate unit or work on patients when the top cover is open WARNING Do not use this device for dental implant procedures CAUTION Do not run salin...

Page 5: ...color coded to identify different fluids e g sterile water or distilled water 6 Place the foot control on the floor 7 Attach power cord to the back of the unit Fig 5 and plug into a grounded electric...

Page 6: ...tor into the amalgam manifold Tighten the retaining screw located under the top cover Fig 10 NOTE Before installing the separator into the manifold remove the two caps from the inlet and outlet ports...

Page 7: ...ESSURE RELEASE TOGGLE BOTTLE SELECTOR TOGGLE AUXILIARY WATER CONNECTION AUXILIARY AIR CONNECTION OPTIONAL SCALER COOLANT VALVE OPTIONAL HANDPIECE SCALER CURING LIGHT HOLDERS ELECTRIC MOTOR CONNECTOR H...

Page 8: ...10V OUTLET AIR TANK PURGE TOGGLE WASTE COMPARTMENT ACCESS DOOR OPTIONAL 220V OUTLET QUICK DIS CONNECT FOR WASTE HOSE 1 AMP CIRCUIT BREAKERS 2 TANK DRAIN OPTIONAL 10 AMP CIRCUIT BREAKERS 2 FOR 220V 20...

Page 9: ...PASS FILTER FILTER REGULATOR OPTIONAL FIBER OPTIC CURING LIGHT MODULE SYSTEM PRESSURE GAUGE PRESSURE REGULATOR CENTRAL VACUUM CANNISTER W AMALGAM SOLIDS TRAP INSIDE OPTIONAL OPTIONAL OPTIONAL OPTIONAL...

Page 10: ...oved from its holder and the foot control is pressed The amount of air pressure supplied to the pneumatic handpieces may be adjusted by turning the flow control screws on the control block OPERATION F...

Page 11: ...bout 5 seconds after every patient and about 20 seconds at the beginning of each day To flush a handpiece remove it from its holder and point the spray nozzle away from you i e into a basin Flip the f...

Page 12: ...atio s from the five available options Refer to page 12 for complete instructions on Customizing Ratios 3 Press the SPEED Up Down buttons to select the desired operating speed for the handpiece being...

Page 13: ...de press the Torque Up Down buttons to select the desired illumination in 10 increments from 10 to 100 The handpiece LED will automatically turn on and change intensity 4 Press the TORQUE Up Down butt...

Page 14: ...ttings a beep will sound 4 Press the foot pedal to activate the motor and begin operation as the adjustments are made The display icon will blink as the adjustments are made To exit the adjustment mod...

Page 15: ...100 On FACTORY DEFAULTS The optional Electric Motor Module will retain the factory default settings Fig 25 in memory until changed by the user To recall the original factory defaults press and hold th...

Page 16: ...ly electric scaler system that provides adjustable ultrasonic levels and a water coolant system The scaler includes 3 instrument tips The 37 instrument is specially developed for subgingival scaling f...

Page 17: ...alve and control valve are provided to turn coolant to the handpiece and motor On and Off and to control the flow Turn the coolant air control valve clockwise until it seats softly Begin turning count...

Page 18: ...t the water lines weekly Prepare a 1 10 bleach solution 1 part household bleach to 9 parts water Purge all water lines see page 17 Purging Water From the System Fill water bottles with bleach solution...

Page 19: ...ll water is purged from the lines with air Finally hold the water syringe over the basin and hold down the water button until all water is purged from the line with air GENERAL CLEANING The external s...

Page 20: ...e Lazer is a product of Kinetic Instruments Inc The curing probe is fully autoclavable Detach probe by pressing quick disconnect button on side of handle Clean probe with disinfectant then autoclave a...

Page 21: ...anchor eye bolts on the base as shown in Figure 38 7 Place the foot control pedal under the cart as shown in Figure 39 8 Wrap the cart with palletizer stretch wrap Fig 40 9 Insert the two end panels a...

Page 22: ...protective foam packing blocks on the front and top of the Cart Ensure the Cart s dental instrument holders are aligned with the cutouts on the top packing block carefully rotate the Cart s pivoting...

Page 23: ...ressure Insufficient vacuum Insufficient handpiece operation No water to handpiece No coolant air to handpiece Unit is turning On and Off Correction Check system power connection Check voltage selecto...

Page 24: ...w High Vol open 42 5 liters min 3 8 cm Hg Simultaneous Vacuum High 4 Hg 5 1 SCFM 144 4 liters min 10 2 cm Hg Low 1 5 Hg 1 4 SCFM 39 6 liters min 3 8 cm Hg Vacuum Compressor Pump 115 PSI 7 92 bar 2 HP...

Page 25: ...e Water Coolant Control Air Coolant ON OFF Toggle OR Flush Toggle Bottle Pressure Release Toggle Bottle Select Toggle Footswitch On Off Switch Mains Temperature Limitation Manufacturer Humidity Limita...

Page 26: ...LGAM SOLIDS TRAP OPEN TYPE AA 29 1 AMALGAM SOLIDS TRAP OPEN TYPE AA 29 100 100 AMALGAM SOLIDS TRAP CLOSED TYPE AA 290VS 1 AMALGAM SOLIDS TRAP CLOSED TYPE AA 290VS 100 100 VALVE DELUXE UNIVERSL AUTOCLA...

Page 27: ...of such action In the event of alleged defect under warranty the purchaser is to notify Aseptico s Customer Service Department promptly Customer Service will provide instructions usually directing th...

Page 28: ...P N 420869 Rev M ECO 14212 06 2017 PRINTED IN THE U S A P O Box 1548 Woodinville WA 98072 8333 216th Street SE Woodinville WA 98072 425 487 3157 800 426 5913 www aseptico com info aseptico com...

Reviews: