Installation
How the ASIN Aqua SALT system is connected to the filtration circuit is shown in
fig. Wiring diagram
The input of measurement water to probes must be connected behind the filter pump and the output
before the filtration pump or into the drain. Water is pushed around the probes by the pressure
difference.
The probes for measuring pH and free chlorine (or alternatively redox) are screwed into the probe holder
on the side of ASIN Aqua SALT. Tighten all only manually, without using pliers or spanners.
ASIN Aqua SALT is mounted onto the wall vertically by two 5 x 40 screws into 8 mm dowels. The maximum
distance of ASIN Aqua SALT from the TE27 electrode is 1,5 m.
ASIN Aqua SALT is connected to the electrode TE27 by a bunch of cables, which are a part of the electrode
(they cannot be disconnected).
ASIN Aqua SALT should never be placed near heat sources or in direct sun, ASIN Aqua SALT must always be
mounted vertically. There is a deflector cooler on the back side of the ASIN Aqua SALT unit, around which
air must flow freely to prevent overheating.
The TE27 electrode (fig.2) is glued into the DN50 output pipe between the filter and pool. It is put in by
gluing or screwing the electrolyser into the pipe according to the diagram in fig. 1. The gluing or screwing
set is not part of the delivery.
5
35,7 cm