background image

EN

EP.V.32907.02 | 04/2021

USER MANUAL

Safety storage cabinets for storage 

 

and charging of lithium ion batteries

10 YEARS WARRANTY

 

Upon conclusion of an asecos service and maintenance agreement 

(PREMIUM 

tariff)

, you will get a warranty extension for up to 10 years for your ION-LINE safety 

storage cabinet.

Summary of Contents for ION LINE

Page 1: ...e cabinets for storage and charging of lithium ion batteries 10 YEARS WARRANTY Upon conclusion of an asecos service and maintenance agreement PREMIUM tariff you will get a warranty extension for up to...

Page 2: ...IO90 195 060 K9 WDC IO90 195 060 L8 WDC IO90 078 059 057 U9 S IO90 195 120 K3 WDC ION CHARGE 90 ION CHARGE PRO 90...

Page 3: ......

Page 4: ...s hochwertigen Materialien das h chste Qualit t garantiert Sicherheitsschr nke aus dem Hause asecos verf gen ber eine l ckenlose Zulassungs Dokumen tation Wir archivieren Ihre Zulassungsdokumente jede...

Page 5: ...ackaging 7 2 3 In plant transport 8 2 4 Q Mover 8 2 5 Titling onto the side wall 9 3 ERECTION 9 3 1 Alignment Of The Cabinets 9 3 2 Commissioning 9 4 CLOSING 10 4 1 In general 10 5 INTERIOR FITTINGS 1...

Page 6: ...are to be kept closed By assigning trained authorised technical personnel you can prevent the malfunctions damage and corrosion damage that result from inappropriate transport Observe the upper limit...

Page 7: ...y if the cabinet is transported to the place of its use by our specially trained staff ATTENTION The doors must be locked prior to transport The extraction unit is inside the cabinet and is only mount...

Page 8: ...inet and is only mounted after the in plant transport to the place of use IO90 195 120 K3 WDC IO90 195 060 K9 WDC IO90 195 060 L8 WDC 1 2 4 3 IO90 078 059 057 U9 S 1 2 3 1 2 3 2 4 Q MOVER Order no 300...

Page 9: ...Doors with an automatic closing mechanism must close automatically from every position and the lock must be able to lock Q CLASSIC 90 Q PEGASUS 90 Q PHOENIX 90 4 2 max 2 3 3 2 COMMISSIONING Before pu...

Page 10: ...ot being accessed In general it must be noted that the cabinets do not possess an emergency unlocking facility This means that persons trapped inside the cabinet cannot free themselves 5 INTERIOR FITT...

Page 11: ...s The individual power socket strip may not be loaded with more than 3 68 kW The necessary fuse protection is to be provided by the customer 6 STORAGE ATTENTION Never store obviously damaged lithium i...

Page 12: ...ontinuously A distance of at least 100 mm must be kept to the area of the fire suppression unit 8 BATTERY FIRE EVENT OF FIRE DISPOSAL CAUTION After a battery fire and triggered fire suppression device...

Page 13: ...13 IO90 195 120 K3 WDC IO90 195 060 K9 WDC IO90 195 060 L8 WDC 1 2 3 4 5 IO90 078 059 057 U9 S 1 2 3 4 5 1 2 3 4 5...

Page 14: ...personnel e g fire brigade Depending on the duration of the fire an ignitable vapour air mixture may have formed therefore remove all ignition sources within a 10 metre radius around the cabinets bef...

Page 15: ...15...

Page 16: ...cess inside the cabinet The exhaust air from the cabinet is exhausted directly into the room Connection to an exhaust duct is not absolutely necessary 9 2 CONNECTION TO THE POWER SUPPLY Connections on...

Page 17: ...that no intervention in the electrical components is necessary 9 3 SELF TEST 2 3 4 5 6b 9 4 ERROR DURING SELF TEST 1 2 5 3 5 sec 4 5 ATTENTION After pressing the reset button the self test begins agai...

Page 18: ...HE POWER SUPPLY Connections on the headpiece 1 2 Mains plug connector Potential free switch contact 1 2 230 V 3 1 2 400 V 3 NOTE Retrofitting is easy due to the plug in connection so that no intervent...

Page 19: ...19...

Page 20: ...ntact 1 2 230 V 3 power failure 11 2 SELF TEST 11 3 WARNING MESSAGE 50 C 1 2 3 Actions Immediate visual inspection of the system by the company s own qualified personnel Initiation of necessary action...

Page 21: ...e alarm control panel FACP is not recommended or may only be carried out in consul tation with the person responsible for the system However it is always recommended to connect the signal to a manned...

Page 22: ...THE POWER SUPPLY Connections on the headpiece 1 2 Mains plug connector Potential free switch contact NOTE Retrofitting is easy due to the plug in connection so that no intervention in the electrical c...

Page 23: ...23...

Page 24: ...Exhaust air DN 75 Top view 290 1129 156 155 9 0 Fresh air Exhaust air DN 75 Top view IO90 195 060 K9 WDC 290 1129 156 155 9 0 Fresh air Exhaust air DN 75 Top view 290 151 Active exhaust air fan Fresh...

Page 25: ...ternal dimensions W x D x H mm 470 x 452 x 582 450 x 522 x 1647 450 x 522 x 1647 1050 x 522 x 1647 Weight without interior equipment kg 130 265 265 424 Distributed load kg m 461 00 894 00 894 00 531 0...

Page 26: ...a 77 ES 08130 Santa Perp tua de Mogoda Barcelona 34 902 300385 34 902 300395 info asecos es asecos bv Veiligheid en milieubescherming Tuinderij 15 NL 2451 GG Leimuiden 31 172506476 31 172506541 info a...

Reviews: