12
13
GENERAL NOTES
GENERAL NOTES
8.2. OPENING THE CABINET AFTER THE FIRE
*ATTENTION:
Only open the cabinet after it has cooled down. This is 6 times the fire duration!
Only authorised personnel (e.g. fire brigade) may open the cabinet!
Depending upon the duration of the fire an ignitable vapour/air mixture may have formed; therefore remove
all sources of ignition within a 10 metre radius of the cabinet before opening it use only spark-free tools
open the cabinets with extreme caution
8.3. DISPOSAL
The models can be disposed of once they have been dismantled and the materials sorted. They are free
from materials that have to be disposed of as special waste.
9. SAFETY CHECKS
9.1. ALL MODELS
As safety equipment (according to §4 Paragraph 3 Workplace Ordinance, §10 German Ordinance on Industrial
Health and Safety and German Statutory Accident Insurance [DGUV] rule no. 108-007) the cabinets have to
be checked for safety at least once per year. The next checking date can be taken from the check sticker on
the outside of the door. This annual check can be carried out with the necessary care, and for securing your
warranty claims in the case of fire, only by an authorised asecos employee (refer also to our service brochure
regarding this).
9.2. IO90.195.120.K3.WDC
A necessary service is automatically indicated by the cabinet by a flashing green LED.
Within the context of the annual check, the fire suppression system, smoke detector and sensors will be che-
cked in addition to the checking of all safety-related parts.
9.3. IO90.195.060.K9.WDC
A necessary service is indicated by service sticker on the door of the cabinet.
Within the context of the annual check, all safety-related parts, the smoke detector and the alarm signalling will
be checked.
ATTENTION
In accordance with DIN 14676 the proper function of the smoke detector must be checked at least once
per year.
In addition, we recommend the regular visual inspection of the battery chargers, batteries and connecting
cables.
9.4. CONTACT
In case of damage please contact your dealer in order to have the cabinet repaired using original spare parts.
The cabinets can be cleaned with a mild household cleaner and a soft cloth.
CONTACT
In the case of defects or complaints about our products (within and also after the warranty period), and for
requesting safety checks or taking out a service contract, please contact our service hotline on:
Tel: +44 1785 22 70-90
10. IO90.195.120.K3.WDC
10.1. INSTALLATION OF THE EXTRACTION UNIT
1
2
3
4
5
6
CAUTION:
The extraction unit is for the avoidance of a heat accumulation in the interior during the charging process
inside the cabinet. The exhaust air from the cabinet is exhausted directly into the room. Connection to an
exhaust duct is not absolutely necessary.
10.2. CONNECTION TO THE POWER SUPPLY
LED: Operating (green)
RESET BUTTON
LED: Error (red)
Connections on the headpiece:
1
2
3
Mains connection for
extraction unit
Mains plug connector
Potential-free switch
contact
Connection to the
power supply
1
2
230 V
3
Connection to the power
supply with 400 V
(optional with item
HF.E.32822)
1
2
400 V
3
Summary of Contents for BATTERY CHARGE
Page 12: ...22 23...