background image

IS-PM824    Effective Date: 0915-1 

EDP# 81012455 

© Watts, 2009

Limited Warranty:

 Watts Radiant (the “Company”) warrants each product to be free from defects in material and workmanship under normal usage for a period of one year from the date of original 

shipment.  In the event of such defects within the warranty period, the Company will, at its option, replace or recondition the product without charge.  

THE WARRANTY SET FORTH HEREIN IS GIVEN EXPRESSLY AND IS THE ONLY WARRANTY GIVEN BY THE COMPANY WITH RESPECT TO THE PRODUCT.  THE COMPANY MAKES NO OTHER 

WARRANTIES, EXPRESS OR IMPLIED.  THE COMPANY HEREBY SPECIFICALLY DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO THE IMPLIED 

WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE.

The remedy described in the first paragraph of this warranty shall constitute the sole and exclusive remedy for breach of warranty, and the Company shall not be responsible for any incidental, special 

or consequential damages, including without limitation, lost profits or the cost of repairing or replacing other property which is damaged if this product does not work properly, other costs resulting 

from labor charges, delays, vandalism, negligence, fouling caused by foreign material, damage from adverse water conditions, chemical, or any other circumstances over which the Company has no 

control.  This warranty shall be invalidated by any abuse, misuse, misapplication, improper installation or improper maintenance or alteration of the product.  

Some States do not allow limitations on how long an implied warranty lasts, and some States do not allow the exclusion or limitation of incidental or consequential damages.  Therefore the above 

limitations may not apply to you.  This Limited Warranty gives you specific legal rights, and you may have other rights that vary from State to State.  You should consult applicable state laws to 

determine your rights.  

SO FAR AS IS CONSISTENT WITH APPLICABLE STATE LAW, ANY IMPLIED WARRANTIES THAT MAY NOT BE DISCLAIMED, INCLUDING THE IMPLIED WARRANTIES OF 

MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, ARE LIMITED IN DURATION TO ONE YEAR FROM THE DATE OF ORIGINAL SHIPMENT.

Slab

Maximum 100A Heating Load

120/208/240VAC

2 circuits

Pole-mount sense

PM-224

or PM-824

Junction

Box

Circuit Breaker Panel

Junction

Box

Contactor Control 2C

Ground

120 / 208 / 240 VAC

Ground

120 / 208 / 240 VAC

Maximum 70A breakers

Ground

L1
L2

T1
T2

Ground

L1
L2

T1
T2

Ground

C1

C2

S1 S2 Y2

Ground

Gr

Ground

Y2

Yel

S2

Br

Bl

Yel

S1

Use size 18- to 24-gauge 4-conductor

wire, outdoor rated (telephone wire).

L1
L2 / N

L1
L2 / N

Slab

Maximum 100A Heating Load

277VAC

2 circuits

Pole-mount sense

PM-224

or PM-824

Junction

Box

Circuit Breaker Panel

Junction

Box

Contactor Control 2C

Ground

277 VAC

Ground

277 VAC

Maximum 70A breakers

Ground

L1
L2

T1
T2

Ground

L1
L2

T1
T2

Ground

C1

C2

S1 S2 Y2

Ground

Gr

Ground

Y2

Yel

S2

Br

Bl

Yel

S1

Use size 18- to 24-gauge 4-conductor

wire, outdoor rated (telephone wire).

Ground

120 VAC

Ground

120V

PRI

L1
L2 / N

L1
L2 / N

Delay Adjust

Temp Adjust

Sensitivity Adjust

Probe Jack

Grid Jack

Switch Jack

Control/Monitor Jack

LED Jack

Configuration Switch

Load

Input Power

Recommended Switch Settings

Function

Trigger

LD Off

LD on

LTC

DEL

RAIN

SNOW

Snow sensor  
w/o LTC

TT>AT

 2 min

 2 min

OFF

OFF

OFF

ON

Snow sensor  
w/LTC

TT>AT>15°F

2 min

2 min

ON

OFF

OFF

ON

Snow controller 
w/o LTC

TT>AT

30-90 min

2-6 hr

OFF

ON

OFF

ON

Snow controller 
w/LTC

TT>AT>15°F

30-90 min

2-6 hr

ON

ON

OFF

ON

Do Not set the Rain switch to "ON".  Possible overheating of the  
snowmelt cables may result.

Supply Voltage

22 - 28 VAC

Trigger Temperature Range (TT)

34°F to 44°F

Configuration Modes 

Snow Only

Rain Only

Snow or Rain

Delay Settings (post melting)

30 to 90 minutes

2 to 6 hours

Low Temperature Cutoff (LTC)

Prevents system operation 

when Ambient Temperature 

(AT) is below 15°F

Operation Modes

Automatic

Standby/Reset

Manual

Reviews: