18
3 - Product coding
3.2
CONFIGURATION CODING
The configuration code consists of
4 digits that identify the operat-
ing characteristic of the controller,
as chosen by the user.
Section 4.6 at page 35 reports the
instructions how to set a new con-
figuration code.
The configuration code can be dis-
played on the front panel, follow-
ing the instructions at page 21 sec-
tion 4.2.2.
I L M N
Conf
2002
Input type and range
I
TR Pt100 IEC751
0
TR Pt100 IEC751
1
TC L Fe-Const DIN43710
2
TC J Fe-Cu45% Ni IEC584
3
TC T Cu-CuNi
4
TC K Chromel -Alumel IEC584
5
TC S Pt10%Rh-Pt IEC584
6
DC input 0…50 mV, linear
7
DC input 10…50 mV, linear
8
Custom input and range
[1]
9
-328…752 °F
32…2192 °F
32…2912 °F
-99.9…572.0 °F
-328…1112 °F
32…1112 °F
32…1112 °F
-200 …400 °C
0…1200 °C
0…1600 °C
Engineering units
-99.9…300.0 °C
Engineering units
-200…600 °C
0…600 °C
0…600 °C
Control action type
M
Reverse (single action)
Direct (single action)
0
Linear Cool (Heat/Cool double action)
1
On-Off Cool (Heat/Cool double action)
Heat/Cool
action
6
7
Control mode Output configuration [2]
L
Control OP1- OP3 / alarm AL2 on OP2
PID
0
Control OP1- OP2 / alarm AL2 on OP3
Control OP1 / alarm AL2 on OP2
1
Control OP2 / alarm AL2 on OP1
On - Off
2
Control OP1 / alarm AL2 on OP2
3
Control OP2 / alarm AL2 on OP1
Control OP2- OP3 / alarm AL2 on OP1
8
[1]
For instance, other thermocouples types,
∆
T (with 2 PT 100), custom
linearisation etc.
[2]
Each control output can be replaced by the OP4 analogue output.
The replaced output is not more available
(see page 34).
M4UK.ed6 20-05-2005 11:43 Pagina 18