55
General Data - Heatpump
1) ALL SPECIFICATION ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.
2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151.
3) NOMINAL COOLING CAPACITY IS BASED ON THE CONDITIONS BELOW:
a) COOLING - 27°C DB / 19°C WB INDOOR AND 35°C DB / 24°C WB OUTDOOR
b) HEATING - 20°C DB INDOOR AND 7°DB / 6°C WB OUTDOOR
4) SOUND PRESSURE LEVEL ARE ACCORDING TO THE JIS B 8615 STANDARD. POSITION OF THE MEASUREMENT POINT IS 1.0 m IN FRONT AND 1.0 m BELOW
THE UNIT
Btu/h
W
Btu/h
W
W
W
A
A
V/Ph/Hz
W/ W
W/ W
CFM /
l
/s
CFM /
l
/s
CFM /
l
/s
dBA
mm/in
mm/in
mm/in
mm/in
mm/in
mm/in
kg/lb
mm/in
CFM /
l
/s
dBA
mm/in
mm/in
mm/in
mm/in
mm/in
mm/in
kg/lb
LIQUID
mm/in
GAS
mm/in
kg/lb
630 (700) / 24.8 (27.6)
630 (700) / 24.8 (27.6)
19.05 / 3/4
FLARE
50 / 110
983 / 38.7
405 / 15.9
328 / 12.9
785 / 30.9
757 / 6.67
4 WAY AUTOMATIC LOUVER (UP & DOWN)
230 /1/ 50
OUTDOOR EXV
WIRELESS OR WIREDE MICROCOMPUTER REMOTE CONTROL
3.2
R410A
250 (295) / 9.8 (11.6)
570 (640) / 22.4 (25.2)
570 (640) / 22.4 (25.2)
317 (127) / 12.5 (5)
450 / 212
430 / 203
410 / 194
47 / 46 / 44
1,646 (497 - 1,856)
1,645 (520 - 2,191)
A5CKX 20CR
A5LCX 20CR
5,275 (1,465 - 5,862)
18,000 (5,000 - 20,000)
19,000 (5,000 - 21,000)
5,668 (1,465 - 6,155)
7.23 (2.10 - 8.12)
7.22 (2.20 - 9.61)
REFRIGERANT CHARGE
HIGH
LOW
DEPTH
HEIGHT
WIDTH
DEPTH
WIDTH
OUT
D
OOR UNI
T
UNIT DIMENSION
() - WITH PANEL
DEPTH
UNIT WEIGHT (UNIT + PANEL)
PACKING
DIMENSION ()
- PANEL
HEIGHT
WIDTH
SOUND PRESSURE
CONDENSATE DRAIN SIZE
PACKING
DIMENSION
OPERATION
UNIT DIMENSION
SOUND PRESSURE (H/M/L)
AIR FLOW
NOMINAL TOTAL INPUT POWER (COOLING)
NOMINAL TOTAL INPUT POWER (HEATING)
NOMINAL RUNNING CURRENT (COOLING)
AIR FLOW
IN
D
O
O
R
U
N
IT
CONTROL
NOMINAL RUNNING CURRENT (HEATING)
MEDIUM
POWER SOURCE
REFRIGERANT CONTROL (EXPANSION DEVICE)
NOMINAL COOLING CAPACITY
NOMINAL HEATING CAPACITY
INDOOR UNIT
OUTDOOR UNIT
MODEL
EER
REFRIGERANT TYPE
1.3 / 2.86
12.7 / 1/2
6.35 / 1/4
TYPE
HEIGHT
DEPTH
WIDTH
HEIGHT
COP
3.45
UNIT WEIGHT
PIPE CONNECTION
SIZE
1500 / 708
23 + 2 / 50.7 + 4.4
53
855 (+70) / 33.7 (+2.7)
AIR DISCHARGE
Summary of Contents for A5LCX 10 C
Page 15: ...13 MODEL A5CMX20E A5LCX20C A5CMX25E A5LCX25C MODEL A5CMX20ER A5LCX20CR ACMX25ER A5LCX25CR...
Page 16: ...14 MODEL A5CCX20C A5LCX20C A5CCX25C A5LCX25C MODEL A5CCX10C A5LCX10C A5CCX15C A5LCX15C...
Page 17: ...15 MODEL A5CCX20CR A5LCX20CR A5CCX25CR A5LCX25CR MODEL A5CCX10CR A5LCX10CR A5CCX15CR A5LCX15CR...
Page 20: ...18 Installation Installation Diagram...
Page 109: ...107 Indoor Unit MODEL A5WMX 20 25 G GR WITH IONIZER Outdoor Unit MODEL A5LCX 20 25 C CR...
Page 110: ...108 MODEL A5CKX 10 15C CR c w A5LCX 10 15 C CR...
Page 111: ...109 MODEL A5CKX 20C CR c w A5LCX 20C CR...
Page 112: ...110 MODEL A5CKX 20 25A AR c w A5LCX 20 25C CR...
Page 113: ...111 MODEL A5CMX 20 25E ER c w A5LCX 20 25C CR...
Page 114: ...112 MODEL A5CCX 10 15C CR c w A5LCX 10 15C CR...
Page 115: ...113 MODEL A5CCX 20 25C CR c w A5LCX 20 25C CR...
Page 127: ...125 MODEL A5CKX 20 25A AR...
Page 129: ...127 MODEL A5CKX 10 15 20C CR...
Page 131: ...129 MODEL A5CMX 15 20 25E ER...