Ascon tecnologic vP4 Installation Manual Download Page 4

vP

4

vP 

=  visualPac (CPU of the Programmable Logic Controller with integrated I/O and Display)

AI1 and AI2 Analogue Inputs

 

AA

  =  2 x 0/4... 20 mA Analogue Inputs

 

CC

  =  2 x PT100 Analogue Inputs

 

MM

 =  2 x PT1000 Analogue Inputs

 

NN

 =  2 x NTC Analogue Inputs

 

TT

  =  2 x TC (Thermocouple) Analogue Inputs

 

VV

  =  2 x 0/1... 5 V or 0/2... 10 V Analogue Inputs

LCD Display

 

4

  =  4.3” Graphic display

AI3 Analogue Input

 

-

  =  Not present

 

A

  =  2 x 0/4... 20 mA Analogue Input

 

C

  =  2 x PT100 Analogue Input

 

M

  =  2 x PT1000 Analogue Input

 

N

  =  2 x NTC Analogue Input

 

T

  =  2 x TC (Thermocouple) Analogue Input

 

V

  =  2 x 0/1... 5 V or 0/2... 10 V Analogue Input

OT1... OT2 Analogue Output

 

-

  =  Not present

 

A

  =  2 x 0/4... 20 mA Anologue Output

 

F

  =  2 x Frequency (PWM) Anologue Output

DI1... DI8/DI1... DI6 + 2 CNT + 8 Digital Inputs

 

62

  =  6 Digital 2 CNT Digital 8 Digital Outputs

 

88

  =  8 Digital 8 Digital Outputs

Packaging ad Case

 

A

  =  Gray case + neutral packaging

 

G

  =  Gray case + Ascon Tecnologic packaging

X6 - OT1... OT2 0/4... 20 mA Analogue Output Connections

+    -

X2

X3

X5

  DO1    DO3    DO5    DO7    GND
GND   DO2    DO4    DO6    DO8

X6

X4

  

RS485

-

+  GND

   AI1   

AI2    AI3

  +    -  +    -    +    -

PB

USB

X8

+   

-

X2

X3

X5

  DO1    DO3    DO5    DO7    GND
GND   DO2    DO4    DO6    DO8

X6

X4

  

RS485

-

+  GND

 AI1   

AI2    AI3

+    -  +    -    +    -

PB

USB

X8

Load

Load

GND_AO

0/4... 20 mA Analogue Outputs

+

+

X4

GND_PWM

GND_PWM
AO/PWM 2

AO/PWM 2
AO/PWM 1

AO/PWM 1
GND_AO

GND_AO

ANALOG

ANALOG

PWM OUT

PWM OUT

 - Respect the polarity shown;

 - Resolution: 14 bit;

 - Accuracy: 0.1%;

 - In the drawing are connected only 2 

outputs as an example  

(OT3 and OT4).

0/4... 20 mA analogue output:

 - Type: 0/4... 20 mA;

 - Load: < 500 

Ω

;

Verify the option ordered for 

OT1... OT2 Outputs.

X6 - OT1... OT2 PWM/Frequency Output Connections

+    -

X2

X3

X5

  DO1    DO3    DO5    DO7    GND
GND   DO2    DO4    DO6    DO8

X6

X4

  

RS485

-

+  GND

   AI1   

AI2    AI3

  +    -  +    -    +    -

PB

USB

X8

+   

-

X2

X3

X5

  DO1    DO3    DO5    DO7    GND
GND   DO2    DO4    DO6    DO8

X6

X4

  

RS485

-

+  GND

 AI1   

AI2    AI3

+    -  +    -    +    -

PB

USB

X8

Load

Load

GND_PWM

PWM Outputs

X4

GND_PWM

GND_PWM
AO/PWM 2

AO/PWM 2
AO/PWM 1

AO/PWM 1
GND_AO

GND_AO

ANALOG

ANALOG

PWM OUT

PWM OUT

V

DD

 - Respect the polarity shown;

 - Output range: 0.1... 200000 Hz;

 - Max. Output load: 10 mA;

 - V

DD

 should be less than or equal to 

Power Supply (24 Vdc);

 - The terminal PWM_GND can be 

used as Ground reference;

PWM Output:

•  0.1... 500 Hz selectable duty-

cycle with 0.1% accuracy,

•  0.5... 3 kHz selectable duty-cycle 

with 1% accuracy,

Frequency Output:

•  3... 200 kHz duty-cycle: 

fixed at 50%.

Verify the option ordered for 

OT1... OT2 Outputs.

How to Order

Summary of Contents for vP4

Page 1: ... local regulations Avoid to use electromagnetic contactors power relays and high power motors nearby Avoid power units nearby especially if controlled in phase angle Keep the low level sensor input wires away from power lines and output cables Power lines and output cables must also be at 100 mm min away from the CPU If this is not achievable use shielded cables on the sensor inputs with the shiel...

Page 2: ...24 V active outputs The current consumption of each output must not exceed 0 5 A and their cumulative output current must be less than 1 6 A whatever the feeding method m Warning Counter Inputs CNT1 and CNT2 are installed as an alternative to Digital Inputs DI7 and DI8 Terminals connections and plugs m Warning In the drawing and in the table that follow are listed and briefly described all the ter...

Page 3: ...NT2 Count Inputs DIG7 DIG7 CNT1 CNT1 DIG8 DIG8 CNT2 CNT2 X6 DI1 DI3 DI5 GND DI1 DI3 DI5 GND 24V DI2 DI4 DI6 24V DI2 DI4 DI6 In the drawing are connected the counter inputs as an example CNT1 and CNT2 Frequency meter input The channels can manage up to 10 kHz signals having a duty cycle that guarantees minimum of ON OFF signal of 20 ms Impulse counter input The minimum time of an impluse must be 20...

Page 4: ...3 PB USB X8 X2 X3 X5 DO1 DO3 DO5 DO7 GND GND DO2 DO4 DO6 DO8 X6 X4 RS485 GND AI1 AI2 AI3 PB USB X8 Load Load GND_AO 0 4 20 mA Analogue Outputs X4 GND_PWM GND_PWM AO PWM 2 AO PWM 2 AO PWM 1 AO PWM 1 GND_AO GND_AO ANALOG ANALOG PWM OUT PWM OUT Respect the polarity shown Resolution 14 bit Accuracy 0 1 In the drawing are connected only 2 outputs as an example OT3 and OT4 0 4 20 mA analogue output Type...

Reviews: