Ascon tecnologic vP4 Installation Manual Download Page 2

Electrical connections

+   

 

+   

    

--

DIG7

DIG7

CNT1

CNT1

DIG8

DIG8

CNT2

CNT2

X1

X2

X3

 PWR

 PWR

  24V

  24V

X5

  DO1    DO3    DO5    DO7    GND

  DO1    DO3    DO5    DO7    GND
GND   DO2    DO4    DO6    DO8

GND   DO2    DO4    DO6    DO8

X6

 

DI1    DI3    DI5     

GND

 

DI1    DI3    DI5     

GND

24V    DI2    DI4    DI6

24V    DI2    DI4    DI6

X4

GND_PWM

GND_PWM
AO/PWM 2

AO/PWM 2
AO/PWM 1

AO/PWM 1
GND_AO

GND_AO

  

RS485

  

RS485

   --   +  GND

+  GND

   AI1   

AI2    AI3

   AI1   

AI2    AI3

  +    -  +    -    +    -

  +    -  +    -    +    -

HMI USB

HMI USB

PB

PB

USB

USB

ETH

ETH

RU
N

RU
N

MSGMSG

USBUSB

COMSCOMS

PWRPWR

HMI ETH

HMI ETH

X7

X8

ANALOG

ANALOG

PWM OUT

PWM OUT

Conn.

Label

Connection

Signals

X1

PWR 24 V

+

+24 Vdc Power Supply

-

0 Vdc Power Supply

X2

COM

D-

RS485 Serial Port

D+

C

X3

IN1... IN3

-

Generic Analogue Input 1... 3 terminals  (mA, TC, Pt100, Pt1000, NTC, Potentiometer, Voltage)

+

X4

AO/PWM

PWM Ground Generic PWM Outputs Ground

AO/PWM2

Generic Output 2 (mA, PWM DO)

AO/PWM1

Generic Output 1 (mA, PWM DO)

AO Ground

Generic AO Ground

X5

DO1... DO8

GND

Ground reference for Digital Outupt (max. current: 1.6 A)

DO1... DO8

Digital Output 1... 8 (24 V, 0.5 A each max.)(

Warning

)

X6

DI1... DI8

24V

+24 Vdc Digital Inputs Power Supply

DI1... DI8

24 Vdc Digital Input 1... 8 (EN61131 - type 1, 2 and 3) (

Warning

)

GND

Ground reference for Digital Inputs

CNT1... CNT2

GND

Special Inputs 1... 2 Common Terminal

CNT1... CNT2

Pulse Counter, Frequency Meter CNT1... CNT2 

or

 

Digital Input 7... 8 (

Warning

)

X8

USB

USB type A port

X7

ETH

RJ45 10/100 Ethernet port

Near the 

X8

 USB connector are present 5 diagnostic LEDs (COM, USB, MSG, PWR) fully described in the vP4 User Guide.

Warning!

 

Digital Outputs DO1... DO8 (connector 

X5

) are 24 V active outputs.  

The current consumption of each output must not exceed 0.5 A and their cumulative 

output current must be less than 1.6 A 

(whatever the feeding method)

.

Warning! 

Counter Inputs 

CNT1 and CNT2

 are installed as an alternative to Digital Inputs 

DI7 and DI8

 

Terminals connections and plugs

Warning!

 

In the drawing and in the table that follow, are listed and briefly described all the terminals present on the vP4 system.  

The different Digital input options (8 DI or 6 DI + 2 Frequency Counter inputs) must be specified while composing the Order Code.

Sytem Pushbutton and Status LEDs

+    -

X2

X3

X5

  DO1    DO3    DO5    DO7    GND
GND   DO2    DO4    DO6    DO8

X6

X4

  

RS485

-

+  GND

   AI1   

AI2    AI3

  +    -  +    -    +    -

PB

USB

X8

+   

-

X2

X3

X5

  DO1    DO3    DO5    DO7    GND
GND   DO2    DO4    DO6    DO8

X6

X4

  

RS485

-

+  GND

   AI1   

AI2    AI3

+ -

+

-

+ -

PB

USB

X8

RU
N

RU
N

MS
G

MSG

US
B

USB

COM

S

COMS

PW
R

PW
R

PB

PB

RU
N

RU
N

MSGMSG

USBUSB

COMSCOMS

PWRPWR

PB

PB

System pushbutton

Status LEDs

 - Near the X8 USB connector is pre-

sent the System Pushbutton fully 

described in the vP4 User Guide

 - The 5 Status LEDs are: 

COM (green), USB (white), 

MSG (RED), PWR (blue) and RUN 

(green).

 - The meaning of the various LEDs 

behaviours are fully described in 

the “

vP4 User Manual

”.

The system pushbutton per-

forms different operations ac-

corndingly to the system status 

but does not restart the CPU or 

the 1131 application.

X1 - Power supply

+    -

X2

X3

X5

  DO1    DO3    DO5    DO7    GND
GND   DO2    DO4    DO6    DO8

X6

X4

  

RS485

-

+  GND

   AI1   

AI2    AI3

  +    -  +    -    +    -

PB

USB

X8

+   

-

X2

X3

X5

  DO1    DO3    DO5    DO7    GND
GND   DO2    DO4    DO6    DO8

X6

X4

  

RS485

-

+  GND

 AI1   

AI2    AI3

+    -  +    -    +    -

PB

USB

X8

+   

 

+   

   

--

X1

 PWR

 PWR

  24V

  24V

+   

 

+   

   

--

X1

 PWR

 PWR

  24V

  24V

Power Supply connector

+  - 

24 Vdc

 - Connector X1: 24 Vdc 

(–10... +15%);

 - Device power consumption: 

10

 W max..

Add a standard 24 V, 8 A fuse to 

protect the vP4.

Summary of Contents for vP4

Page 1: ... local regulations Avoid to use electromagnetic contactors power relays and high power motors nearby Avoid power units nearby especially if controlled in phase angle Keep the low level sensor input wires away from power lines and output cables Power lines and output cables must also be at 100 mm min away from the CPU If this is not achievable use shielded cables on the sensor inputs with the shiel...

Page 2: ...24 V active outputs The current consumption of each output must not exceed 0 5 A and their cumulative output current must be less than 1 6 A whatever the feeding method m Warning Counter Inputs CNT1 and CNT2 are installed as an alternative to Digital Inputs DI7 and DI8 Terminals connections and plugs m Warning In the drawing and in the table that follow are listed and briefly described all the ter...

Page 3: ...NT2 Count Inputs DIG7 DIG7 CNT1 CNT1 DIG8 DIG8 CNT2 CNT2 X6 DI1 DI3 DI5 GND DI1 DI3 DI5 GND 24V DI2 DI4 DI6 24V DI2 DI4 DI6 In the drawing are connected the counter inputs as an example CNT1 and CNT2 Frequency meter input The channels can manage up to 10 kHz signals having a duty cycle that guarantees minimum of ON OFF signal of 20 ms Impulse counter input The minimum time of an impluse must be 20...

Page 4: ...3 PB USB X8 X2 X3 X5 DO1 DO3 DO5 DO7 GND GND DO2 DO4 DO6 DO8 X6 X4 RS485 GND AI1 AI2 AI3 PB USB X8 Load Load GND_AO 0 4 20 mA Analogue Outputs X4 GND_PWM GND_PWM AO PWM 2 AO PWM 2 AO PWM 1 AO PWM 1 GND_AO GND_AO ANALOG ANALOG PWM OUT PWM OUT Respect the polarity shown Resolution 14 bit Accuracy 0 1 In the drawing are connected only 2 outputs as an example OT3 and OT4 0 4 20 mA analogue output Type...

Reviews: