Installation Guide
PCR Charging Rack
2
2
Safety Instructions
For safe and efficient operation, observe the guidelines given in this manual and all
necessary safety precautions. Follow the operating instructions and adhere to all warnings
and safety precautions located on the product and this Installation Guide.
The Power Supply module connects to 100 - 250 V AC. Therefore extra caution should be
taken during operation.
IMPORTANT:
Power Supply CR24 is the only power supply that can be used together
with the PCR Charging Rack.
• For safety the covers must always be mounted during operation.
• The voltage safety cover in the Power Supply module has to be mounted on top of the
voltage connector to prevent hazardous situations like electric shock.
• Ensure that the Power Supply is grounded after installation by measuring between the
power supplies metal shield cover and an external ground. The Power Supply unit can
otherwise be live.
• When working with the units the mains power supply cable must always be
disconnected. Note the following:
-
for PERMANENTLY CONNECTED EQUIPMENT, a readily accessible disconnect device
shall be incorporated in the building installation wiring
-
for PLUGGABLE EQUIPMENT, the socket-outlet shall be installed near the
equipment and shall be easily accessible
The disconnect device shall disconnect both poles simultaneously.
• For continued protection against risk of fire only replace the fuse in the Charging Rack
with the same type and rating of fuse (4A ATAB Art. No. 210265).
• Every installation must at least consist of one Power Supply CR24 and one Charging
Rack Master PCR-M.
If the ambient temperature is 25 °C or lower the Power Supply CR24 can supply up to
three
Charging Racks (Master PCR-M and Extension PCR-E).
If the ambient temperature is higher than 25 °C the Power Supply CR24 can supply up
to
two
Charging Racks (Master PCR-M and Extension PCR-E).
One Master PCR-M can support up to 20 Extensions PCR-E.
• Suomi: Laite on liitettävä suojamaadoituskoskettimilla varustettuun pistorasiaan.
• Norge: Apparatet må tillkoples jordet stikkontakt.
• Sverige: Apparaten skall anslutas till jordat uttag.
Information to user
This device complies with Part 15 of the FCC Rules. Operation is subject to the following
two conditions:
(1) this device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that may
cause undesired operation.
Modifications
Changes or modifications to the equipment not expressly approved by the party
responsible for compliance could void the user’s authority to operate the equipment.