INSTALLATION GUIDE
Card Reader (NUCR-HE)
6
Connecting to a door
The NUCR offers two auxiliary functions: a relay circuit for switching an external device, such as an
electrically operated door lock, and a pair of connections for monitoring, such as door open detection. The
relay connection is a potential-free contact (“normally open” / “normally closed”) and the monitoring
connections consist of ground (GND) and two return lines (IN0/IN1).
Figure 1. NUCR Electrical connections for an electric door lock
Legend
1.
DC electric door lock. A surge dampening diode is needed only with DC power
2.
Electric door lock power supply (max. 30Vdc)
3.
Door monitoring contact (NO/NC)
The door lock relay and monitoring inputs must be configured in the vNISM GUI. See the Configuration
Manual (TD93442EN) for details.
TD 93429EN / 18 March 2022 / Ver. C
8