background image

Installation instructions, BS330 base station

Technical Product Manual - DCT1800-GAP

TD 92093 (1/LZBNB 103 108 R4D) / 2005-09-23/ Ver.C

 2005

70

1.

Stick the brand label in the front cover recess.

16.3.9 Connecting the base station cables

1.

If it is required that the cables enter the base station centrally from above, guide the cables through the 
recess in the middle of the base station as shown in figure 41.

Fig. 41  Cables entering the base station centrally from above

2.

Plug the modular jack of the data cable into one of the data/power connectors.

3.

When an AC-adapter is used:

– Plug the modular jack of the AC-adapter in one of the data/power connectors.

– Plug the AC-adapter into a wall-outlet.

Note:

 

See also chapter 22

‘CLU/CLU-S/SLU to base station cabling’

16.3.10 Mounting the base station

1.

Hold the base station flat against the mounting bracket and move it downwards until it clicks (see figure 42).

Note:

 

After completion of the installation, base stations must be initialized using the cordless system manager.

Power cable
(if used)

Data cable

043

Summary of Contents for BS330

Page 1: ... mounting bracket Two screws with wall plugs Note The brand label is not included in the box but must be ordered separately Power distribution Base stations can be powered by the following sources The radio exchange via the data pairs The radio exchange via the data and Express Powering Pairs EPP A 48 V external supply connected to the radio exchange A local AC adapter Note For more information ab...

Page 2: ...our LED see table 1 Fig 35 BS330 base station Status of LED2 Meaning Off Base station operational and no traffic on the base station Green Base station operational and traffic on the base station Red Base station is malfunctioning Amber Base station is OK but not available self test not initialized no communication with radio exchange Flashing green All 8 channels are in use Flashing amber Softwar...

Page 3: ...ty reversal Data pairs may not be interchanged It is assumed that service personnel know how to crimp these connectors to a cable Do not power the base station via the EPP terminals from a local power source and the radio exchange simultaneously As the two EPP inputs of the base station are interconnected in the base station the two power sources would be interconnected see figure 36 However the b...

Page 4: ...e right way up and mark the two holes The minimum distance between the upper hole and the ceiling or any object above the base station must be at least 65 mm see figure 37 If the distance is less than 65 mm the base station cannot be slid onto the bracket 2 When using wall plugs take a 6 mm drill and drill the two holes and insert the included wall plugs 3 Position the mounting bracket with its fl...

Page 5: ...tion points downwards 16 3 3 Fixing the mounting bracket to a pole or beam The mounting bracket can be fixed to a pole diameter 45 mm or a beam wider than 50 mm by means of a strap or flexible metal band less than 30 mm wide The strap or flexible metal band must be purchased locally 1 Fix the mounting bracket to a pole or beam such that the text TOP is right way up see figure 38 Fig 38 Fixing the ...

Page 6: ...asons secure the base station cable to a convenient point at about 30 cm from the base station If for some reason the base station drops the cable is pulled out of the base station 16 3 6 Connecting the base station plug to the cable 1 Cut the base station cable to the correct length and connect the cable to a RJ45 modular jack see figure 40 Do not plug the connector in the base station yet Note T...

Page 7: ...base station 1 Make sure that the base station cable is unplugged from the base station 2 Disconnect relevant connector from the relevant CLU CLU S or SLU 3 Connect an echo meter to cable pair SC0 or SC1 4 Measurethecabledelay Themeasureddelayisthetimebetweensendingapulsedownthelineandreceiving the echo Therefore the recorded value is twice the cable delay and must be halved The resulting value mu...

Page 8: ...ering the base station centrally from above 2 Plug the modular jack of the data cable into one of the data power connectors 3 When an AC adapter is used Plug the modular jack of the AC adapter in one of the data power connectors Plug the AC adapter into a wall outlet Note See also chapter 22 CLU CLU S SLU to base station cabling 16 3 10 Mounting the base station 1 Hold the base station flat agains...

Page 9: ...Installation instructions BS330 base station Technical Product Manual DCT1800 GAP TD 92093 1 LZBNB 103 108 R4D 2005 09 23 Ver C 2005 71 Fig 42 Mounting the base station 044 ...

Page 10: ...Installation instructions BS330 base station Technical Product Manual DCT1800 GAP TD 92093 1 LZBNB 103 108 R4D 2005 09 23 Ver C 2005 72 ...

Reviews: