INSTALLATION GUIDE
9dLD Locator, Version D

3

TD 92775EN / 14 December 2020 / Ver. D

2.

Board Description

The 9dLD consists of two circuit boards, a radio circuit board and the 9dLD circuit board shown 

in figure below. The radio circuit board is screwed tight onto the bottom side of the 9dLD circuit 

board. The placement of components are shown in figure below. 

Connectors

J1:

Pin 1 and 2: Monitor out
Pin 3 and 4: Monitor in

J2:

Pin 1 and 2: Supply voltage
Pin 3–5: RS232 used for parameter update and software download 

to the 9dLD. 

1A – 1B:

Antenna SMA connectors (female) for location 1

2A – 2B:

Antenna SMA connectors (female)  for location 2

LEDs

LED1:

Green LED that indicates that the 9dLD is operational and is 

synchronized to the system.

Switches

SW1:

Reed relay (on reverse side)- for tamper protection.

SW01 – SW02:

Switches used to adjust the RSSI threshold value for location 1.

SW03 – SW04: Switches used to adjust the RSSI threshold value for location 2.

Jumpers

1A:

Tamper monitoring of antenna 1A.

1B:

Tamper monitoring of antenna 1B.

2A:

Tamper monitoring of antenna 2A.

2B:

Tamper monitoring of antenna 2B.

X:

Short circuit detection

Y:

Open circuit detection

001

1A      1B

2A

2B

SW03

SW04

SW01

SW02

LED1

SW1

Spacers for internal antenna

Location 1            Location 2

Magnet

position

Antenna connector

Jumper

2A  2B 1A 1B X  Y 

J2

J1

1

1

4

5

Summary of Contents for 9dLD

Page 1: ...INSTALLATION GUIDE 9dLD Locator Version D...

Page 2: ...ON GUIDE 9dLD Locator Version D Abbreviations and Glossary LAL Location Area Level PARK Primary Access Rights Key PLI PARK Length Indicator RSSI Radio Signal Strength Indicator TD 92775EN 14 December...

Page 3: ...ntenna 7 5 2 Mount External Antennas 8 5 2 1 Tamper Monitoring of External Antennas 8 6 Installation 9 6 1 Connect Supply Voltage 9 6 2 Connect RS232 10 7 Configuration 11 7 1 Parameter Template 11 7...

Page 4: ...tory Compliance Statements USA only FCC Compliance Statements This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to part 15 of the FCC Rules These...

Page 5: ...to the following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation Modif...

Page 6: ...emale for location 1 2A 2B Antenna SMA connectors female for location 2 LEDs LED1 Green LED that indicates that the 9dLD is operational and is synchronized to the system Switches SW1 Reed relay on rev...

Page 7: ...s are mounted nor are cable entry holes drilled thus making it possible to find the most appropriate cable entry positions upon installation Drill holes and push cable entries into positions Below is...

Page 8: ...dLD box is chosen with internal antenna recommended mounting height is equal to carrying height of the handset about 1 5 m 1 2 1 8 m For mounting with external antennas refer to the DECT Location Vers...

Page 9: ...75EN 14 December 2020 Ver D Figure 3 Mounting the lid NOTE When the case of the 9dLD is put together make sure that the reed relay and the tamper protection magnet are placed opposite each other see b...

Page 10: ...erving that reed relay and tamper protection magnet are placed opposite each other Notes 1 Antennas and antenna cables with male SMA connectors are accessories 2 It is never recommended to mix interna...

Page 11: ...s 4 Feed antenna cable through protective conduits to 9dLD box where cable is fed through cable entry Tighten all antenna cable connectors relatively hard for good electrical connection 5 2 1 Tamper M...

Page 12: ...or AWG13 Connect supply voltage polarity independent to pin 1 and 2 on J2 as shown in Figure 4 Connecting supply voltage to 9dLD on page 9 Figure 4 Connecting supply voltage to 9dLD IMPORTANT 9dLD sho...

Page 13: ...4 December 2020 Ver D 6 2 Connect RS232 Figure 5 Connecting RS232 to 9dLD The RS232 connection on the 9dLD is used for parameter settings and software download to the 9dLD 005 1 2 3 TX 4 GND 5 RX J2 1...

Page 14: ...or apply a template with common parameters and then add the individual settings refer to the Ascom Portable Device Manager WinPDM Installation and Operation Manual TD 92325EN 4 Connect the 9dLD locat...

Page 15: ...uded in the location transmission Default 0000 NOTE Location 2 can have a unique location ID but it can also have the same ID as location 1 RSSI threshold A handset with DECT Location feature enabled...

Page 16: ...Function Description TD 92629EN for more information about how to set the threshold value 7 4 Locator Monitoring The monitor output is a galvanically isolated relay contact 15 ohm used for supervisio...

Page 17: ...The last unit in the series has to be strapped Strap J1 1 2 on the 9dLD Depending on the type of Alarm Module and the supply voltage in the monitor loop the following number of units can be connected...

Page 18: ...h once with an orange light and indicates with a steady green light when the 9dLD is operational and is synchronized to the system 3 Use a handset to check that the required coverage is obtained and t...

Page 19: ...Portable Device Manager PDM Windows version 1 Connect the 9dLD location device to the computer with an RS232 cable refer to 6 2 Connect RS232 on page 10 2 Follow the instruction for downloading new s...

Page 20: ...TD 92775EN 14 December 2020 Ver D 10 Related Documents Data Sheet 9dLD Locator Version D TD 92781EN Ascom Portable Device Manager WinPDM Installation and Operation Manual TD 92325EN DECT Location Ver...

Page 21: ...ppendix A Third Party Antennas C 7 May 2012 Added section 1 1 Regulatory Compliance Statements EU EFTA only Edited section 3 Cabling Edited section 4 Mount the 9dLD Box Added instruction to protect th...

Page 22: ...antenna must be modified if detection of open circuit is required 1 Open the antenna casing and take out the antenna board 2 Solder a 1 8 W 3 3 kOhm carbon resistor for example ELFA 60 055 57 to the P...

Page 23: ...INSTALLATION GUIDE 9dLD Locator Version D 20 TD 92775EN 14 December 2020 Ver D...

Page 24: ...Ascom Sweden AB Grimbodalen 2 SE 417 49 Gothenburg Sweden Phone 46 31 55 93 00 www ascom com TD 92775EN 14 December 2020 Ver D...