Operating Instructions Ascoline 700, AEH 35x
ascobloc
Gastro-Gerätebau GmbH
01156 Dresden, Grüner Weg 29
Germany
Tel. +49 351 4533-0
Fax +49 351 4537-339
E-mail:
AEH 35x_d.doc, Status: 19.04.2013
Subject to change without notice!
8
7 Faults and their Rectification
7.1 Fault indication on the display
Short circuit temperature sensor, hob temperature too low < -50°C
Temperature of hob too high, hob temperature sensor interrupted > 260°C
No pan on the hob (pan too small for the hob)
Wrong pan on the hob, short circuit of the induction coil
Heat sink temperature > 100°C or temperature sensor of heat sink short
circuited
Potentiometer is missing or defective
Electronics OK, potentiometer at 0 position
Signal for external indication is missing (external indication disconnected or
SW1/3 switched on)
Switch-on after disconnection of AC phases L1 and L3 to zero < 150 V,
(if L2 drops out, appliance continues to function at reduced power)
Failure of standard I/O DEVICE 1 or 2
Warning: DC current > 350 mA (too many or wrong fans)
Warning: Fan not connected or blocked