Installation

Manual

920

Remote Control Switches

30 through 225 ampere sizes

DANGER is used in this manual to warn of high

voltages capable of causing shock, burns, or death.

WARNING is used in this manual to warn

of possible personal injury.

CAUTION is used in this manual to warn

of possible equipment damage.

!

This Installation Manual is for green nameplate
ASCO 920s only. For black nameplate ASCO
920s refer to Owner’s Manual 2D4920 R16.

ASCO 920 Remote Control (RC) Switches are pre–tested

and ready to use. Installation requires mounting and

connection of service cables (or bus) and control circuit

wires. An experienced licensed electrician should install

the RC Switch.

Each ASCO 920 RC Switch has a ratings / identification

label defining load types and maximum voltage ratings.

Use the switch only within the limits shown on this label.

Do not exceed the values on the rating label.

Exceeding the rating can cause personal injury

or serious equipment damage.

TABLE OF CONTENTS

page

Installation & Maintenance

1

. . . . . . . . . . . . . . . .

Troubleshooting & Parts Kits

2

. . . . . . . . . . . . . .

Optional Accessories

3

. . . . . . . . . . . . . . . . . . . . .

Wiring & Outline Diagrams

back of manual

. . .

Catalog Number Identification with Elements Explained

Typical ASCO 920 catalog no. for 3 pole, 100 amp, 208 volt 60 Hz control, with subpanel and enclosed Remote Control Switch:

920

3

100

6

1

Phase Poles

Product

Amperes

Control Voltage

Accessories

X

3

– three phase

2

– single phase

9

440 – 480 V

7

265 – 277 V

G

550 – 600 V

X

other voltages

920

Enclosure

C

blank – open type

C

Subpanel

0

– without

30

100

150

200

225

75

60

6

208 – 240 V

3

110 – 120 V

50 – 60 Hz

1

– with

if
accessories
ordered

blank – none

Summary of Contents for 920

Page 1: ... or bus and control circuit wires An experienced licensed electrician should install the RC Switch Each ASCO 920 RC Switch has a ratings identification label defining load types and maximum voltage ratings Use the switch only within the limits shown on this label Do not exceed the values on the rating label Exceeding the rating can cause personal injury or serious equipment damage TABLE OF CONTENT...

Page 2: ...es and minimum wire sizes that can be run between a control station and one ASCO 920 switch Table A Line Run Min Wire Size Maximum Distance feet 1 for these AC Control Voltages Wire Size AWG 120 V 208 V 240 V 277 V 14 12 10 750 1200 2000 1650 2600 4200 2760 4300 6900 3950 6350 10000 1 For ambient temperatures to 40 C Do not exceed these distances for proper switch operation Line run can be extende...

Page 3: ...Station Make sure control stations do not have overlapping contacts RC Switch tries to open or close but cannot 1 Check Voltage Make sure control line voltage is at least 90 of nameplate coil voltage 2 Check Line Run Wire Size Make sure control line size and distance is within the requirements of Table A page 1 3 Check VA Burden of Transformer If a transform er is used in the control line make sur...

Page 4: ...ned type control station Acc 53B or 53C Order Catalog 32lA40 and specify relay coil voltage Three Wire Control Optional Accessory 48 Acc 48 is an auxiliary relay panel for 3 wire control of the ASCO 920 It has two relays One relay must be energized to open the ASCO 920 contracts the other relay must be energized to close the ASCO 920 contacts Therefore use a single pole double throw momentary type...

Page 5: ......

Page 6: ......

Page 7: ......

Page 8: ......

Reviews: