Connecting Grounding Wire
When the device is solely connected to protective ground, it should have an independent
path, and share the same ground with other devices. When the device adopts a united path,
the grounding resistance should be smaller than 1
Ω.
Warning
Before connecting power cord to IRD1516 Tuner to IP Gateway, user should set the
power switch to “OFF”.
Users can only control and set configuration parameters using a computer by connecting the
device to a web NMS port. Users should ensure that the computer’s IP address is different
from the IRD1516’s IP address; otherwise it will cause an IP conflict.
The default IP of this device is 192.168.2.136. Connect the pc and the device with an RJ45
Ethernet cable, and use the ping command to confirm that they are on the same network
segment.
For example, if the PC IP address is 192.168.99.252, change the device IP to 192.168.99.xxx
(xxx can be any integer between 0 to 255 except 252 to avoid IP conflict).
Use a web browser to connect the device with the PC by inputting the Encoder & Modulator’s
IP address into the browser’s address bar and press Enter.
Login interface should be displayed as shown in Figure - 1. Input the Username and Password
(the default Username and Password are both “admin”.) and then click “Login” to enter the
device’s settings.