background image

AON126S CATV and SAT-IF Receiver 

 

 

Solutions Provider for FTTx, RFoG, and HFC 

www.ascentcomtec.com 

Page 2 of 13 

 

ACT AON126S CATV and SAT-IF Receiver 

Quick Reference Guide 

ACT Document Number: ACT AON126S Optical Receiver QRG

 

Quick Reference Guide Revision B

 

Copyright © 2019 Ascent Communication Technology Limited. 

 

All rights reserved. Reproduction in any manner whatsoever without the express written permission of Ascent 
Communication Technology is strictly forbidden. 

 

This document is produced to assist professional and properly trained personnel with installation and maintenance 
issues for the product. The capabilities, system requirements and/or compatibility with third-party products 
described herein are subject to change without notice. 

 

 
For more information, contact ACT

[email protected]

 

 

 

 

 

Revision Bistory

 

Revision 

Date 

Reason for Change 

A

 

08/05/2018 

Initial release 

 

 

Summary of Contents for AON126S

Page 1: ...AON126S CATV and SAT IF Receiver Quick Reference Guide Revision A...

Page 2: ...tion in any manner whatsoever without the express written permission of Ascent Communication Technology is strictly forbidden This document is produced to assist professional and properly trained pers...

Page 3: ...2 2 Features 6 2 3 Specifications 7 2 4 Block Diagram 8 2 5 Interface 8 2 6 Models and Options 9 3 Configuration and Installation 9 3 1 Housing 9 3 2 Equipment Inventory 9 3 3 Power and Cooling Requi...

Page 4: ...s Damage requiring service Unplug unit and refer servicing only to Ascent Communication Technology qualified service personnel Servicing Do not attempt to service this unit yourself Refer all servicin...

Page 5: ...swab or cleaning fabric Never touch any portion of a tissue or swab where alcohol was applied Never touch the dispensing tip of an alcohol bottle Never use alcohol around an open flame or spark alcoho...

Page 6: ...Hz 950 MHz to 2600 MHz High performance and cost effective CATV SAT IF ONU solution for FTTX networks Small form factor and low power consumption Optional integrated WDM to pass through PON signals to...

Page 7: ...s 1 5 dB Output Impedance 75 Return Loss 10 dB RF Type F 5 Imperial Qty of Output Ports 2 identical Link Performance1 CNR 51 0 dB CTB 61 0 dB CSO 60 0 dB SAT IF Frequency Range 950 MHz to 2600 MHz Fla...

Page 8: ...ning STAT Power Red Green ON Powered OFF No power Optical Light Green ON Fiber in 12 dBm Red ON Fiber 12 dBm or no input Fiber Types Classification Remarks DC IN Power supply Power Supply Input DC12v...

Page 9: ...s and the bottom housing contains the RF connection ports Four Cabinet Mount Holes are equipped which allow the optical node to be pedestal mounted On receiving your new AON126S unit you should carefu...

Page 10: ...idual setup scenarios however it is important to permit free air flow across the front and sides of the unit Warning Exposure to class 1M laser radiation is possible Access should be restricted to tra...

Page 11: ...er Symbol Value Saturation power Ps 2 0 mW Forward current If 2 0 mA Reverse voltage Vr 15 V Operating temperature Top 40 C to 85 C Storage temperature Tstg 40 C to 125 C Optical and Electrical Charac...

Page 12: ...o low or too high and must be adjusted externally to the unit for optimal performance If the optical level entering the unit is too high it could cause permanent damage to the unit The signal should b...

Page 13: ...A Unit 1933 600 Luban Road 2710 Thomes Ave 200023 Shanghai CHINA Cheyenne WY 82001 USA Phone 86 21 60232616 Phone 1 203 816 5188 EUROPE VIETNAM Pfarrer Bensheimer Strasse 7a 15 F TTC Building Duy Tan...

Reviews: