The AON126S requires an external supply of 11 V DC to 16 V DC. The maximum power
consumption of the unit is 3 W. A universal 12 V DC power supply plug-pack is supplied with
the unit, and is suitable for 95 V AC to 265 V AC 50/60 Hz with selectable mains pins for
Australia, Continental Europe, United Kingdom and United States.
The AON126S is specified for operation between 0 °C to +50 °C. Ensure that the unit is
mounted in such a way as to permit airflow around the front and sides at all times.
The AON126S has four mounting holes to fix the unit to the inside of a wiring closet or meter
box. The AON126S is designed to be a flexible and environmentally-friendly unit and as such
can be mounted in a number of ways to suit individual setup scenarios; however it is
important to permit free air flow across the front and sides of the unit.
Warning
Exposure to class 1M laser radiation is possible. Access should be restricted to trained
personnel only.
1.
Ensure that the unit is complete with all expected equipment
2.
If you are mounting the unit in a wiring closet or meter box, do this
before
connecting the optical and coaxial cables. Keep in mind appropriate clearances for
these cables, air flow etc.
3.
Connect the RF OUT port to the RF signal output.
4.
Optical Input Port: Connect to forward fiber with SC/APC connector
5.
PON Pass Port: Connect to PON signal fiber with SC/APC connector.
6.
Connect CATV+PON and PON Pass to the CATV Coaxial network and the ONU.
7.
Connect power to the unit via the power port
8.
Ensure that the Power Status Alarm LED is green. Off is no power.
9.
Check that the Optical Status LEDs is on. Optical input power is within -12 ~ 0dBm
10.
User can adjust the RF Output power by the adjustable attenuator: Output level
adjustment range of 0 to 20 dB.