Maintenance & Repair Manual
SECTION 3
VIRTUOSO 5460P
26
110057 REV K
3.12 Operating Stations
The operating stations house the UP/DOWN rocker switches and, on the station inside
the lift car, the emergency stop button. To test or remove either of these switches, use
a Phillips screwdriver to remove the two (2) screws that secure the switch plate to the lift
car and pull the plate away from the lift car. A standard multi-meter can be used to test
the switches.
To remove the rocker switch, depress the mounting tabs and push the switch out of its
mounting cutout.
To remove the emergency stop button, use a Phillips screwdriver to loosen the two (2)
mounting screws on the mounting block, twist the button counterclockwise, and pull the
mounting block free of the button.
To remove the terminal block from the mounting block, use a standard screwdriver to
turn the screw in the terminal block counterclockwise until the terminal block can be
pulled free.