Caution: To reduce the risk of fire, use metal ductwork.

1. Decide where the ductwork will run between the ventilator unit and the

 

outside.

2. A straight, short duct run will allow the ventilator to perform most efficiently.

3. Long duct runs, elbows, and transitions will reduce the performance of the ventilator. Use as few of 

them as possible. Larger ducting may be required for best performance with longer duct runs.
4. It is recommended that a 6” round metal duct be used.

5. The air must not be discharged into a flue that is used for exhausting fumes from appliances burning 

gas or other fuels. Regulations concerning the discharge of air must be fulfilled. 

6. Install a roof/wall cap. Connect round ductwork to cap and work back

towards hood location. Use duct tape to seal the joints between ductwork sections.

ELECTRICAL CONNECTIONS:

* Electrical wiring must be done by a qualified person(s) in accordance with all applicable local building 

codes and standards. 

TURN OFF ELECTRICAL POWER AT SERVICE ENTRANCE BEFORE WIRING

* If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly 

qualified persons in order to avoid a hazard.
* Do not use the plug and an extension cord other than the ones initially provided with the unit.

INSTALLATION:

1. Attach the duct outlet adapter to the top

of the ventilator with the four screws provided.

Tighten securely.

2. The ventilator is designed to be operated

with a 6” exhaust duct.

4

Summary of Contents for SY-HVA-500-SS

Page 1: ...Range Hood Ventilator Instruction Manual READ AND SAVE THESE INSTRUCTIONS Copyright 2016 Castlewood by AMS All rights reserved SY HVA 500 SS...

Page 2: ...ectrical appliances i e natural gas burning appliances a sufficient degree of ventilation must be guaranteed in the room in order to prevent the backflow of exhaust gas The kitchen must have a direct...

Page 3: ...e unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety Children should be supervised to ensure that they do not play with the...

Page 4: ...issues are present Do Not Install the Unit Bring it back to the store where it was purchased Note 1 On stainless steel units carefully remove the protective plastic film from the face plate and filter...

Page 5: ...rge of air must be fulfilled 6 Install a roof wall cap Connect round ductwork to cap and work back towards hood location Use duct tape to seal the joints between ductwork sections ELECTRICAL CONNECTIO...

Page 6: ...a hole might have to be made in the wall to accomodate it 2 Unscrew the 2 visable screws located on the face plate of the ventilator unit the eight mounting holes around the perimeter of the unit are...

Page 7: ...ng by rinsing with clear water Wipe dry with a clean soft cloth to avoid water marks For discolorations or deposits that persist use a non scratching household cleanser or stainless steel polishing po...

Page 8: ...ed installation instructions The duration of any implied warranty is limited to the one year period as specified in the expressed warranty CASTLEWOOD by AMS Inc s OBLIGATION TO REPAIR OR REPLACE AT IT...

Reviews: