A-4
Preliminary November 4, 1998
MAX 4000 Series Hardware Installation Guide
Provisioning the Switch
Provisioning the switch for ISDN BRI access
Table A-3 provides provisioning information for Northern Telecom switches.
Note:
The MAX can receive multichannel calls using Combinet or MP encapsulation only if
all channels of the call share a common phone number (namely, a hunt group). You can request
that your service provider supply you with a hunt group.
Number of Circuit Switched
Data (CSD)
2
Except when it handles calls to digital modems,
the MAX is a data device, and you can substitute
voice service for data service only if end-to-end
data integrity is guaranteed. Voice service is
required if digital modems are installed.
Number of Circuit Switched
Voice (CSV)
1
Except when it handles calls to digital modems,
the MAX is a data device, and you can substitute
voice service for data service only if end-to-end
data integrity is guaranteed. Voice service is
required if digital modems are installed.
Number of Call
Appearances
1
Not relevant for proper operation of the MAX.
Ringing/Idle Call
Appearances
Idle
The default for Terminal Type A.
Autohold is Y/N
No
The default for Terminal Type A.
Onetouch is Y/N
No
The default for Terminal Type A.
Table A-3. Northern Telecom provisioning information
Element
Value
Comments
Signaling
Functional
Protocol Version Control
(PVC)
1 or 2
1 is NTI custom.
2 is NI-1 (National ISDN-1), which
requires a TID to be assigned as a suffix
to the SPID.
TEI assignment
Dynamic
Release Key
No
Not relevant for proper operation of the
MAX.
Ringing Indicator
No
Not relevant for proper operation of the
MAX.
EKTS (Electronic Key
Telephone System)
Off
Table A-2. AT&T 5ESS provisioning information (continued)
Element
Value
Comments