ON/OFF COFFEE GROUPS
We can deactivate coffee groups independently by pressing key 5 and immediately
and without releasing this one also key 2 of each keypad. The display on the left of
the off group will show OFF. To activate it again, we must repeat the operation again,
pressing buttons 5 and 2 simultaneously
PARAMETERS
Tx
- TEMPERATURE OF THE COFFEE GROUP
To select the different groups, we will use the key “S” and will confirm the group with
the key “XL”. Then we will increase or decrease the temperature according to our
choice.
Once the temperature is set we will confirm the selection by pressing the “XL” key.
•
T1 Left group
•
T2 Right group (2GR) Central group (3GR)
•
T3 Right group (3GR)
Tc
– BOILER TEMPERATURE
To change the temperature of the steam boiler.
Tec
– PID PARAMETERS
P/I/D/B are parameters to configurate the PID control. We advise not to change.
Ce
– POWER CONFIGURATION
In this section we can configure the amount of heating elements that can be
connected at the same time. With this we can control consumption so that it does not
exceed 25A.
The heating element of the groups is always prioritized
See table settings
CAFE (W)
VAPOR
(W)
A TOTAL
230V 1P
PARAMETRO CE
1
2
3
4
5
6
BARISTA T 1GR 1 x 1000
2 x 1000
13
4,5 A
9 A
13 A
13 A
13 A
13 A
BARISTA T 2GR 2 x 1000
2 x 1750
24
8 A
15,5 A
20 A
24 A
24 A
24 A
BARISTA T 3GR 3 x 1000
2 x 1750
29
8 A
15,5 A
20 A
24 A
29 A
29 A
TABLA DE POTENCIAS/AMPERAJE MODELOS ONE/PLUS