Installing Port Expansion Modules
Page 2-7
Installing Port Expansion Modules
Up to three optional port expansion modules
can be installed in the IntraCore
8000, in addition to a stack matrix module. (A stack matrix module is needed
only if more than two units are stacked together. See “Stacking Switches.”)
To install any combination of Gigabit Ethernet Switch (GBIC) modules and
8-port 10/100 Switch modules, use the following procedure.
I
Important: Make sure the IntraCore 8000 is properly
installed in an equipment rack or resting on a flat, stable
surface. Also make sure the power cord is disconnected
for initial installation.
1
Remove the cover plate from the slot where you intend to
install the expansion module.
2
Align the bottom of the expansion module with the rails
inside the IntraCore 8000 slot, as shown in Figure 2-2.
3
Slide the module into the slot until it stops, then push the
module in gently until it seats with the connector.
Figure 2-2 Installing port expansion module
4
Tighten the thumbscrews at the ends of the module’s face
plate. Use a straight-bladed screwdriver so the thumb-
screws cannot be loosened by hand.
Installation of the module is complete. Repeat this procedure for each
module you have purchased.
I
Important:
Do not remove modules from the IntraCore
8000 unless you are a qualified System Administrator.
Summary of Contents for IntraCore 8000
Page 1: ...IntraCore 8000 Ethernet Switch User s Manual August 2000 Part Number 06 00566 00...
Page 8: ...Page vi...
Page 34: ...Installation and Setup Page 2 16...
Page 90: ...Configuration Page 3 56...
Page 140: ...Advanced Management Page 4 50...
Page 149: ...Statistics Button Page 5 9 Figure 5 7 Bar graph of counters for a port...
Page 160: ...Web Browser Management Page 5 20...
Page 162: ...Page A 2...