Chassis Installation/Placement
Page 2-3
Chassis Installation/Placement
The IntraCore 8000 can be installed in a standard 19-inch equipment rack. It
can also be placed on a stable horizontal surface.
I
Important: The equipment rack or desk on which you
install your IntraCore 8000
must
be secure and stable.
Equipment racks must be fastened to the floor; desks
must be resting on a flat, stable surface.
Installation in an Equipment Rack
To install the unit in an equipment rack, use the following procedure.
Safety Precautions for Rack Installation
I
Important!
Before continuing, disconnect all cables
from the IntraCore 8000. Also, do not install any optional
modules you have purchased until the switch has been
installed in the rack.
Equipment Rack Guidelines
Table 2-2 Equipment Rack Guidelines
Guideline
Specification
Size
Width; 17.75 inches (45.09 cm).
Depth: 19.25 inches (48.9 cm) to 32 inches (81.3 cm).
Stability
Rack must be bolted to the floor. Mount heavier units at the bottom of the
rack. If the IntraCore 8000 is the only unit, mount it the bottom of the
rack..
Ventilation
Ensure that the rack is installed in a room where the temperature remains
below 40° C (104° F). Ensure also that there are no obstructions, such as
other equipment or cables, blocking airflow to or from the IntraCore 8000
vents.
Clearance
In addition to providing clearance for ventilation, ensure that there is ade-
quate clearance for servicing the modules of the IntraCore 8000 from the
front.
Summary of Contents for IntraCore 8000
Page 1: ...IntraCore 8000 Ethernet Switch User s Manual August 2000 Part Number 06 00566 00...
Page 8: ...Page vi...
Page 34: ...Installation and Setup Page 2 16...
Page 90: ...Configuration Page 3 56...
Page 140: ...Advanced Management Page 4 50...
Page 149: ...Statistics Button Page 5 9 Figure 5 7 Bar graph of counters for a port...
Page 160: ...Web Browser Management Page 5 20...
Page 162: ...Page A 2...