Installation, Operation and Maintenance Manual
【
H-A070-E-3
】
3-Way Ball Valve Type23 Pneumatic Actuated Type AR 15-50mm (1/2”-2”)
8
9. Specifications of limit switch box
Actuation
Nominal size
Type sign
Switch contact
Protection grade
Double acting
Air to open
Air to shut
15-50mm
(½”-2”)
CFC-6301 Silver
contact
IP67 (IEC529)
CFC-6302
Gold contact
(
Micro-load
)
Ratings
Type sign Rated voltage
Max current
CFC-6301
250V AC
10 A
24V DC
2.5 A
CFC-6302
250V AC
0.1 A
24V DC
0.1 A
10. Specifications of speed controller
Actuation
Nominal size
Actuator type
Air
supply
bore
Type sign
Applicable
tube outer
diameter
(mm)
Number of
needle
rotations
Double
acting
15-25mm
(½”-1”)
AR040DA20
Rc1/8
AS2201FG-01-06A
φ
6
11 turns
Air to open
Air to shut
15-20mm
(½”-¾”)
AR040NC20
Double
acting
32-50mm
(1¼”)-2”)
AR050DA30
Rc1/4
AS2201FG-02-06A
φ
6
11 turns
Air to open
Air to shut
25-50mm
(1”-2”)
AR050NC30
AR063NC40
JIS sign
Internal Circuits
Double acting
& Air to open: Left open
Air to shut: Right open
Double acting
& Air to open: Right open
Air to shut: Left open
Solenoid valve side
Valve side