background image

 
 

 

手動バルブ

 

Manual Valve 

取扱説明書

 

User’s Manual 

 

AVSDV-T 

トグル式手動弁 

Toggle Type Manual valve 

 

 
 

Serial No. 

DTS033-04 

                                                       

 

 
 
 
 

 

1   

取扱い使用上の注意

                                    1

 

  General cautions

 

 

   

各部品の名称                   

                  5 

  Part names

 

 

3    仕様  

 

 

 

  6 

       

Specifications

 

 
4    型式選定 

 

 

 

  7 

How to select types

 

 
5    寸法  

 

 

 

  8 

       

Dimension

 

 
6    操作方法                                                          11 
       

How to operate

 

 
7    特性グラフ                                                        13 

Technical data

 

 
8    取付方法 

 

 

 

14 

       

How to installation

 

 
9    配管方法 

 

 

 

15 

       

How to piping

 

 
10  点検項目 

 

 

 

17 

       

Check items

 

 
11  不具合の原因と処置方法 

 

18 

       

Causes of defects 

and how to correct them 

 
12  残材・廃材の処理方法   

 

18 

How to manage debris and waste

 

 

 

                                                                     

 

 

     

Contents

       

   

 

   

  (

Page

 

Summary of Contents for Dymatrix AVSDV-T

Page 1: ...ve Serial No DTS033 04 General cautions Part names Specifications How to select types Dimension How to operate Technical data How to installation How to piping Check items Causes of defects and how to...

Page 2: ...User s Manual AVSDV T 1 General cautions 1 2 AV V 029 EJ N2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 1 2...

Page 3: ...User s Manual AVSDV T 2 1 1 AV V 029 EJ N2 2 3 4 5 6 1 2 3 4...

Page 4: ...alve unable to seal 4 Please contact us when use for the fluid containing the crystalline substance It would make the valve unable to seal 5 Use the products within the range of working pressure shown...

Page 5: ...nding on the working condition If cavitations are observed review the fluid pressure and piping design 3 Do not use the valve in negative pressure It can be damaged 4 Handle the products carefully to...

Page 6: ...ser s Manual AVSDV T 5 Part names Body Diaphragm Actuator O O ring Metal parts SUS304 SUS304 PTFEcoating PTFE PP PVDF FKM EPDM Viflon F Kalrez 6190 Parts Chemical resistant Wetted parts 0 1 PFA or PTF...

Page 7: ...c pressure 23 0 0 25 0 36 25psi Leakage Rate 3 Back Pressure Ambient Temperature Installation direction Connection 5 Orifice diameter CV 4 5 Cv value Items Actuation Medium Temperature Proof Pressure...

Page 8: ...F T R and N connection is not available only I Inch can be selected for the Tubing Standard 5 In the case of Mounting 2 there is some possibility of that the mounting holes are hidden by some is a st...

Page 9: ...Rc FNPT inch 50 72 72 90 110 50 60 89 5 129 5 158 5 22 34 39 112 174 227 5 111 173 5 227 112 175 228 5 30 Size 30 G 5 107 106 107 E 144 F 143 T 7 145 B 40 C 106 5 D 25 5 84 5 18 40 Standard A Flowell...

Page 10: ...r 300 Type Pillar Fitting Flare Type 3 1 Secifications only for the PTFE Body 2 Secifications only for the PFA Body Super 300 Type Pillar Fitting Flare Type 3 It is reference value 1 PTFE 2 PFA Super...

Page 11: ...19 15 8 25 4 22 2 12 10 25 22 12 70 9 53 19 05 15 88 12 7 9 5 6 4 10 8 inch 6 35 4 35 9 53 6 35 3 18 2 18 6 35 3 95 9 53 6 33 Flowell 20 series Flowell 60 series 06 10 12 19 25 6 4 10 8 12 10 19 16 25...

Page 12: ...wn in parallel Upstream side 2 Valve is opened when Handle is raised to vertical and handle is locked 1 2 3 Non Lock Type 1 Valve is closed by spring when Handle is knocked down in parallel Upstream s...

Page 13: ...Handle is knocked down in parallel Upstream side 2 Valve is opened when Handle is knocked down in parallel downstream side and handle is locked Upstream Downstream Upstream Downstream Status Close St...

Page 14: ...Manual AVSDV T 13 Technical date Working pressure Back pressure Differential pressure Flow rate 2 The data shown here is the experimental values and the reference values 1 Cv B 2 1 The data of B type...

Page 15: ...direction of passage and then fix the product to the panel by hand Insert the nut again from the top of the handle and tighten the nut while the panel is pinched to secure the product in firm positio...

Page 16: ...User s Manual AVSDV T 15 How to piping Flowell 20 series 1 2 Flowell 60 series Super Type Pillar fitting Super 300 Type Pillar fitting Flare Type...

Page 17: ...he inner surface of the tube Insert the tube provided with the ring into the main body by hand Turn nut up to the required clearance by spanner after tightening by hand firmly To check the tightness o...

Page 18: ...check them at least once a year When finding any problem or trouble call us Check points Check items Actuator Appearance flaw crack distortion discoloration Unusual noise while the valve opens and clo...

Page 19: ...kage in the fully closed position The diaphragm is abraded Replace the valve Flaw in the diaphragm or body Foreign matter is caught in the valve Outer leakage from the valve The cap nuts are loose Ret...

Page 20: ...e of product improvement 2020 12 v04 110 0005 3 24 6 21 TEL 03 5826 8832 FAX 03 3834 7592 For inquiries contact Head Office Overseas Department Tel 81 3 5826 8831 Fax 81 3 3834 7592 21st Floor Ueno Fr...

Reviews: