background image

取扱説明書

 

User’s  Manual 

AVSDV                                                                                                                                                                                                                                                                                       

 

       

 

         

Warning

 

Follow all product specification and warnings when using these products. 

 

Our company does not guarantee every application, although we are constantly making every effort 
to improve the quality and reliability of these products. The products used in equipment could cause 
serious  physical  damage  or  property  damage,  if  appropriate  and  safe  design  procedures  are  not 
followed. We take no responsibility for these products if there was no written agreement regarding 
the compatibility of the product with the application.

 

 

Please carry it out understanding instructions written in this book or a technical documentation if you 
need assistance on product specification, installation/plumbing, operation and maintenance. 

 

Cautions for design of piping and product selection 

 

Warning

 

1.  Please  choose  from  the  products  within  the  specification  range  of  the  working  conditions  such  as 

medium, working temperature/pressure and so on. 

2. Confirm the fluid compatibility with the wetted part of the products in the "Suitability List on Medium" in 

the  latest  Dymatrix  general  catalogue  (AV-V-029-EJ).  (Parts  may  be  damaged  by  a  kind  of  a 
medium.) Consult us on any medium, which is not listed in "Suitability List on Medium".Moreover, if 
you intend to use it with compressed air or gas (such as air, nitrogen, ozone, or other gas), we do not 
assume product liability of the Product. 

3. If there are foreign substances in a fluid, please install a filter. 

  (

It would make the valve unable to seal.

 

4. Please contact us, when use for the fluid containing the crystalline substance. 

  (

It would make the valve unable to seal.

 

5. Use the products within the range of working pressure shown in this user's manual. 
6. Use the products within the range of working temperature shown in this user's manual. 
7. Use the products within the range of atmospheric temperature shown in this user's manual. Please 

use the products upon confirmation of compatibility with material and atmosphere. Do not adhere any 
fluid to the external surface of product. 

8. Please refers to the latest instruction manual issued by each fitting maker, and attach the fitting as 

instructed. 

9.  When  preparing  the  bypath  piping,  avoid  making  the  circuit  a  sealed  loop,  which  would  cause 

breakage of the piping material. 

10. Secure the maintenance space. 

 

Cautions for installation and plumbing 

 

Warning

 

1. Read in this user's manual (IOM-Manual) carefully prior to installation/plumbing. 
2. Flush the piping completely and make sure that there is no foreign substances in the piping prior to 

installation/plumbing of our product into it. 

3. Confirm the leak inspection is carried out correctly after the installation/plumbing. 
4. Make sure that the valves are free of tensile/compression/bending stresses. 
5. Do not apply excessive load on valve. 
6. Confirm the flow direction of the valve matches the flow direction indication on the body. 
7. Keep the valve away from excessive heat or fire. (It can be deformed or destroyed.) 
8. Do not use the products in a place where they may become submerged in water.

 

 

Caution

 

1. Do not give any impact or drop the products. 
2. Avoid scratching the products with any sharp object. 

 

 

Summary of Contents for Dymatrix AVSDV

Page 1: ...TS004 09 1 General cautions 5 Part names 6 Specifications 8 How to select types 9 Dimension 12 How to operate 7 17 Method of installation 18 Method of piping 20 Check items 0 21 Causes of defects and...

Page 2: ...User s Manual AVSDV 1 General cautions 1 2 AV V 029 EJ N2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 1 2...

Page 3: ...User s Manual AVSDV 2 1 1 AV V 029 EJ N2 2 3 4 5 6 1 2 3 4...

Page 4: ...lve unable to seal 4 Please contact us when use for the fluid containing the crystalline substance It would make the valve unable to seal 5 Use the products within the range of working pressure shown...

Page 5: ...ding on the working condition If cavitations are observed review the fluid pressure and piping design 3 Do not use the valve in negative pressure It can be damaged 4 Handle the products carefully to p...

Page 6: ...s Manual AVSDV 5 Part names 0 1 2 3 Body Diaphragm Actuator O O ring Metal parts Parts Chemical resistant Wetted parts PFA PTFE PTFE PPS PVDF FKM EPDM Viflon F Kalrez 6190 SUS304 SUS304 SUS304 PTFEco...

Page 7: ...value CV Cv value 3 5 Connection Flowell 60 series Flare Type Actuation Air to open Air to close Double acting Items Unit Size 30 40 Medium Temperature 5 90 Proof Pressure 1 0 145psi Working Pressure...

Page 8: ...6 25 22 6 35 4 35 9 53 6 35 12 70 9 53 19 05 15 88 25 40 22 20 Air to open 0 1 0 5 0 8 Air to close 0 1 Double acting 0 1 0 4 0 5 0 2 PTFE Body material PTFE PFA Body material PFA 0 1 0 2 Size 40 0 2...

Page 9: ...User s Manual AVSDV 8 How to select types PFA PFA Body PTFE PTFE Body...

Page 10: ...pe Pillar Fitting inch 69 93 100 129 150 Super 300 Type Pillar Fitting inch 68 PFA 80 PFA 90 PFA 98 PFA 122 PFA 146 PFA Flare Type inch 86 PFA 92 PFA 102 PFA 106 PFA 126 PFA 154 PFA Tube inch 90 100 1...

Page 11: ...Q 7 R 25 S 20 M5L7 5 64 52 40 30 5 5 30 22 4 2 Size 30 40 50 42 indecator Travel stop Bypass indecator Travel stop Bypass PFA Super 300 Type Pillar Fitting Specifications only for the main body of PFA...

Page 12: ...10 25 22 12 70 9 53 19 05 15 88 12 7 9 5 6 4 10 8 inch 6 35 4 35 9 53 6 35 3 18 2 18 6 35 3 95 9 53 6 33 Flowell 20 series Flowell 60 series 06 10 12 19 25 6 4 10 8 12 10 19 16 25 22 6 35 4 35 9 53 6...

Page 13: ...applying the specified pilot pressure When you stop the pilot pressure supply 0MPa the valve will be closed by the spring force IN 0MPa Air to close Connect an air tube to the air coupling screwed int...

Page 14: ...ot pressure supply to the OPEN pilot port and close the valve by applying the specified pilot pressure to the SHUT pilot port Always use compressed air Do not use oil and water or the like That may br...

Page 15: ...ng more than 1 4 turn from the fully closed position If omitted a cavitation and a flow rate fluctuation or the like may occur in a certain condition How to adjust flow rate Option A A Fully close the...

Page 16: ...ing nut is loose the bypass handle also may become loose Always tighten the bypass handle and its locking nut by hand Tightening it with tools excessively may break the product Always use the bypass h...

Page 17: ...User s Manual AVSDV 16 Indicator Option This option is just to show Open or Close status of the valve This option does not indicate the opening and closing degree Close Open Indicator A...

Page 18: ...holes of the bottom of the product For the dimensions see Dimension Flow direction 0 4 0 6N m Be careful about the screw length Fasten the screws to a torque between 0 4 and 0 6 N m Do not overfasten...

Page 19: ...User s Manual AVSDV 18 Method of piping Flowell 20 series 1 2 Flowell 60 series Super Type Pillar fitting Super 300 Type Pillar fitting Flare Type...

Page 20: ...als leakage may occur Preparation 0 4 0 6 N Always use plastic couplings and tighten them to a torque between 0 4 and 0 6 N m Overtightening them by spanner or the like may break the product Metallic...

Page 21: ...ends you to check them at least once a year When finding any problem or trouble call us Check points Check items Valve Appearance flaw crack distortion discoloration Leakage from the valve Tightness o...

Page 22: ...air The pilot pressure is low Check the pilot pressure Leakage in the fully closed position The diaphragm is abraded Replace the valve Flaw in the diaphragm or body Foreign matter is caught in the va...

Page 23: ...se of product improvement 2020 12 v09 AVSDV 2way valve for chemical 110 0005 3 24 6 21 TEL 03 5826 8832 FAX 03 3834 7592 For inquiries contact Head Office Overseas Department Tel 81 3 5826 8831 Fax 81...