![Arwin PG 2300 Translation Of The Original Instructions Download Page 6](http://html1.mh-extra.com/html/arwin/pg-2300/pg-2300_translation-of-the-original-instructions_2979478006.webp)
6
5. Layout
1 Tank indicator
2 Fuel cap
3 230 V~ socket-outlets
4 Motor
5 Earth connection
6 Overload cut-out
7 Voltmeter
8 Oil filler plug
9 Oil drain plug
10 Oil shortage cut-out
11 On/Off switch
12 Choke lever
13 Pull cord
14 Petrol cock
15 Transport handles
16 Spark plug wrench set
17 Push bar assembling set
18 Air filter set
19 Spark plug
20 Muffler
6. Before putting the machine into
operation
6.1 Electrical safety
- Electric supply cables and connected equipment
must be in perfect condition.
- The generator is to be operated only with
equipment whose voltage specifications conform
to the generator's output voltage.
- Never connect the generator to the power
supply (socket-outlet).
- Keep the cable length to the consumer as short
as possible.
6.2 Environmental protection
- Dispose of soiled maintenance material and
operating materials at the appropriate collection
point.
- Recycle packaging material, metal and plastics.
6.3 Connecting to earth
The housing is allowed to be connected to
earth in order to discharge static electricity. To
do this, connect one end of a cable to the earth
connection (5) on the generator and the other
end to an external earth (for example an earthing
rod).
7. Operation
Important!
You must fill up with engine oil (see Fig 2) and
fuel before you can start the engine.
- Check the fuel level and top it up if necessary.
- Make sure that the generator has sufficient
ventilation.
- Make sure that the ignition cable is secured to
the spark plug.
- Inspect the immediate vicinity of the generator.
- Disconnect any electrical equipment which may
already be connected to the generator.
7.1 Starting the engine
- Do not connect the power tool before starting
the motor.
- Open the petrol cock (14) by turning it down.
- Move the ON/OFF switch (11) to position "I”.
- Move the choke lever (12) to position IØI.
- Start the engine with the pull cord (13) by
pulling the handle forcefully. If the engine does
not start, pull the handle again.
- Push the choke lever (12) back again after the
engine has started.
Important!
When starting with the pull cord, the motor may
recoil suddenly as it starts up, resulting in hand
injuries. Wear protective gloves when starting the
equipment.
7.2 Connecting consumers to the generator
Connect the equipment you want to use to the
socket-outlets (3)