Aruba 580EX Series Hazardous Location Outdoor Access Points
| Installation Guide
11
on verifying post-installation network connectivity.
Electrical and Environmental Specifications
Electrical
Ethernet
E0 PoE+ port: 100/1000/2500/5000Base-T auto-sensing MDI/MDI-X wired network port (RJ45). The E0 port
supports PoE-in, allowing the AP to draw power from an 802.3at/802.3bt PoE power source.
E1 SFP+ port: 10GBASE-R SFP+ port.
E2 PSE port: 100/1000Base-T auto-sensing MDI/MDI-X wired network port (RJ45). The AP supports 802.3af
PoE-Out when PoE powered, and supports up to 802.3at when powered by AC.
Environmental
Operating
Temperature: -40ºC to 65ºC (-40ºF to 149ºF)
Storage
Temperature: -40ºC to 70ºC (-40ºF to 158ºF)
Humidity: 5% to 93% non-condensing
For additional specifications on this product, please refer to the data sheet at
www.arubanetworks.com
.
Regulatory Model Number
For the purpose of regulatory compliance certifications and identification, this product has been assigned a
unique regulatory model number (RMN). The regulatory model number can be found on the product nameplate
label, along with all required approval markings and information. When requesting compliance information for
this product, always refer to this regulatory model number. The regulatory model number RMN is not the
marketing name or model number of the product.
The following regulatory model numbers apply to the 580EX Series:
AP-585EX RMN: APEX0585
AP-587EX RMN: APEX0587
Safety and Regulatory Compliance
If the 580EX Series access point is deployed supporting Fiber, PSE, and high user loads in extremely hot
temperatures or in hot environments with large solar loading environments, it is strongly recommended to
enable Intelligent Power and Temperature Monitoring (IPTM) to ensure continuous uninterrupted operations,
allowing the AP to disable specific and user-definable features to ensure continuity and prevent a thermal
shutdown of the AP.
!
RF Radiation Exposure Statement:
This equipment complies with RF radiation exposure limits. This
equipment should be installed and operated with a minimum distance of 9.84 inches (25cm) between the
radiator and your body for 2.4 GHz and 5 GHz operations. This transmitter must not be co-located or operating
in conjunction with any other antenna or transmitter.
!
Déclaration de la concernant l’exposition aux rayonnements à fréquence radioélectrique (FR):
Cet
appareil est conforme aux limites d’exposition aux rayonnements FR établies par la FCC. Il doit être installé et
utilisé à une distance minimale de 25 cm (9,84 pouces) entre le radiateur et votre corps, qu’il opère sur la
bande 2,4 GHz ou 5 GHz. Cet émetteur ne doit pas être installé ou utilisé à proximité immédiate d’une autre
antenne ni d’un autre transmetteur.