![ARTRAY ARTCAM-130SWIR-CL Setting Manual Download Page 15](http://html1.mh-extra.com/html/artray/artcam-130swir-cl/artcam-130swir-cl_setting-manual_2978780015.webp)
© 2004 – 2018 ARTRAY Co., Ltd
130SWIR-CL
Camera Link
Setting Manual
15
Rev.1.04
Table 5-25: Sensitivity Correction OFF
1
2
3
4
Format
s
〼
-n
⏎
Details
1: s = Sensitivity correction
2: Delimiter (Omissible)
3: -n = Option: sensitivity correction OFF
4: Line feed code
Response
Normal: OK
⏎
Abnormal: NG
⏎
Note
To disable sensitivity correction.
5.5.9.
Defective Pixel Correction
Table 5-26: Defective Pixel Correction ON
1
2
3
4
Format
f
〼
-y
⏎
Details
1: f = Defective pixel correction
2: Delimiter (Omissible)
3: -y = Option: defective pixel correction NO (Omissible)
4: Line feed code
Response
Normal: OK
⏎
Abnormal: NG
⏎
Note
To enable defective pixel correction.
Table 5-27: Defective Pixel Correction OFF
1
2
3
4
Format
f
〼
-n
⏎
Details
1: f = Defective pixel correction
2: Delimiter (Omissible)
3: -n = Option: defective pixel correction OFF
4: Line feed code
Response
Normal: OK
⏎
Abnormal: NG
⏎
Note
To disable defective pixel correction.