![ARTRAY ARTCAM-036MI2-BW-WOM Instruction Booklet Download Page 31](http://html1.mh-extra.com/html/artray/artcam-036mi2-bw-wom/artcam-036mi2-bw-wom_instruction-booklet_2978770031.webp)
- 31 -
11.1.3.
Trigger timing chart(ARTCAM-500MI-WOM series)
t0
Input Pulse Width
Above 1ms
t1
Photo Coupler Delay
1~99
μ
s (Subject to Input Pulse Voltage)
t2
Reset Time
8 * 1H
t3
Exposure Time
Subject to Shutter Speed Settings
t4
Frame Transfer
Subject to ROI Settings and Operation Clock
t5
Effective Trigger for next frame
Approximate 100H after the Vertical Synchronization
Signal transits to a low voltage
*1 For ARTCAM-500MI, the image will be acquired when the trigger signal transits from a
low voltage to a high one. If the trigger signal stays at a high level, the trigger time cycle will
repeat automatically and image will be acquired continuously.
*
2
1H
=
(2592+912)
×
0.020833[
μ
s]
Trigger Input
TRIG Signal
Reset Time
1
st
Line
2
nd
Line
Last Line
Vertical Synchronization Signal
Image Transfer (USB)
Exposure
Time
t0
t1
t5
t3
t4
t2