![ARTRAY ARTCAM-036MI2-BW-WOM Instruction Booklet Download Page 10](http://html1.mh-extra.com/html/artray/artcam-036mi2-bw-wom/artcam-036mi2-bw-wom_instruction-booklet_2978770010.webp)
- 10 -
5.
Connections
5.1.
How to connect a camera
5.2.
Shutter Speed
Shutter speed can be changed on the standard viewer software ART-Viewer.
The shutter speed is set directly on the sensor register, so please refer to the following formulas for the
real exposure time.
Model
Method
036MI2-WOM Series
Range
:
1~32767(Exposure Time
:
1/33149~0.988 sec)
*1 External trigger value : 2~32767
Exposure Time
=
(Shutter Value
×
(640+64))
×
0.0417 [
μ
sec]
at 24MHz
130MI-WOM Series
Range
:
1~16383(Exposure Time
:
1/35928~0.52 sec)
Exposure Time
=
(Shutter Value
×
(1280+244)
-
180)
×
0.020833 [
μ
sec]
at 48MHz
300MI-WOM Series
Range
:
1~16383(Exposure Time
:
1/19688~0.832 sec)
Exposure Time
=
(Shutter Value
×
(2048+390))
×
0.020833 [
μ
sec]
at 48MHz
500MI-WOM Series
Range
:
1~16383(Exposure Time
:
1/53452~1.196 sec)
Exposure Time
=
((Shutter Value
×
(2592+912))
-
2606)
×
0.020833 [
μ
sec]
at 48MHz
1000MI-WOM Series
Range
:
1~16383(Exposure Time
:
1/11678~1.4 sec)
Exposure Time
=
(Shutter Value
×
(3856+254))
×
0.020833 [
μ
sec]
at 48MHz
1400MI-WOM Series
Range
:
1~16383(Exposure Time
:
1/9756~1.68 sec)
Exposure Time
=
(Shutter Value
×
(4608+312))
×
0.020833 [
μ
sec]
at 48MHz
5.3.
Operation clock settings
Users can switch the operation clock between 48MHz / 24MHz / 12MHz with the standard viewer
software or SDK.
*1 48MHz is not available on ARTCAM-036MI2-WOM series.